Specifications of EP4CE40F29C8N

Number Of Logic Elements/cells
39600
Number Of Labs/clbs
2475
Total Ram Bits
1134000
Number Of I /o
532
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
780-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CE40F29C8N
Manufacturer:
ALTERA43
Quantity:
1 602
Part Number:
EP4CE40F29C8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE40F29C8N
Manufacturer:
ALTERA
0
Part Number:
EP4CE40F29C8N
Manufacturer:
ALTERA
0
Part Number:
EP4CE40F29C8N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP4CE40F29C8N
0
Company:
Part Number:
EP4CE40F29C8N
Quantity:
2 800
Part Number:
EP4CE40F29C8N ALTERA
Manufacturer:
ALTERA
0
Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices
Remote System Upgrade
Dedicated Remote System Upgrade Circuitry
Figure 8–33. Remote System Upgrade Circuit Data Path
Notes to
(1) The RU_DOUT, RU_SHIFTnLD, RU_CAPTnUPDT, RU_CLK, RU_DIN,RU_nCONFIG, and RU_nRSTIMER signals are internally controlled
(2) The RU_CLK refers to the ALTREMOTE_UPDATE megafunction block "clock" input. For more information, refer to the
© December 2010 Altera Corporation
by the ALTREMOTE_UPDATE megafunction.
(ALTREMOTE_UPDATE) Megafunction User Guide.
Figure
Previous
State
Register 2
Bit[30..0]
8–33:
RU_DIN
Status Register (SR)
Previous
State
Register 1
Bit[30..0]
This section describes the implementation of the Cyclone IV device remote system
upgrade dedicated circuitry. The remote system upgrade circuitry is implemented in
hard logic. This dedicated circuitry interfaces with the user-defined factory
application configurations implemented in the Cyclone IV device logic array to
provide the complete remote configuration solution. The remote system upgrade
circuitry contains the remote system upgrade registers, a watchdog timer, and state
machines that control those components.
remote system upgrade block.
din
RU_SHIFTnLD
Bit [40..39]
Logic
Current
State
Logic
Bit[31..0]
Shift Register
RU_CAPTnUPDT
dout
din
Logic Array
Bit [38..0]
Update Register
Bit [38..0]
Control Register
Bit [38..0]
Logic
(Note 1)
clkout
capture
update
capture
dout
Logic
RU_CLK (2) RU_DOUT
clkin
update
Figure 8–33
RSU
Reconfiguration
State
Machine
RSU
Master
State
Machine
RU_nCONFIG
shows the data path of the
Cyclone IV Device Handbook, Volume 1
Internal Oscillator/
CLKUSR
timeout
RU_nRSTIMER
Remote Update Circuitry
User
Watchdog
Timer
8–73