DF2214BQ16V Renesas Electronics America, DF2214BQ16V Datasheet - Page 20

IC H8S/2214 MCU FLASH 112-TFBGA

DF2214BQ16V

Manufacturer Part Number
DF2214BQ16V
Description
IC H8S/2214 MCU FLASH 112-TFBGA
Manufacturer
Renesas Electronics America
Series
H8® H8S/2200r
Datasheets

Specifications of DF2214BQ16V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
16MHz
Connectivity
SCI
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
72
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
12K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
D/A 1x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
112-TFBGA
For Use With
HS0005KCU11H - EMULATOR E10A-USB H8S(X),SH2(A)3DK2218 - DEV EVAL KIT H8S/2218
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2214BQ16V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Item
12.3.2 Operation in
Asynchronous Mode
Figure 12.10
Sample Serial
Reception Data
Flowchart (1)
Rev.4.00 Sep. 18, 2008 Page xviii of lx
REJ09B0189-0400
Page
497
Revisions (See Manual for Details)
Note added
Note: * The RDRF flag is cleared automatically by DTC
No
No
only when the DTC DISEL bit is 0 and
furthermore the transfer counter is not 0.
Therefore the CPU must clear the RDRF flag
when either DISEL is 1 or when DISEL is 0 and
furthermore the transfer counter is 0.
Read receive data in RDR, and
clear RDRF flag in SSR to 0
PER ∨ FER ∨ ORER = 1
Clear RE bit in SCR to 0
Read RDRF flag in SSR
Read ORER, PER, and
All data received?
FER flags in SSR
Start reception
Initialization
RDRF = 1
<End>
Yes
Yes
No
(Continued on next page)
Error processing
Yes
[1]
[2]
[4]
[5]
[3]
[1]
[2] [3]
[4]
[5]
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
break detection:
If a receive error occurs, read the
ORER, PER, and FER flags in
SSR to identify the error. After
performing the appropriate error
processing, ensure that the
ORER, PER, and FER flags are
all cleared to 0. Reception cannot
be resumed if any of these flags
are set to 1. In the case of a
framing error, a break can be
detected by reading the value of
the input port corresponding to
the RxD pin.
SCI status check and receive
data read :
Read SSR and check that RDRF
= 1, then read the receive data in
RDR and clear the RDRF flag to
0. Transition of the RDRF flag
from 0 to 1 can also be identified
by an RXI interrupt.
Serial reception continuation
procedure:
To continue serial reception,
before the stop bit for the current
frame is received, read the
RDRF flag, read RDR, and clear
the RDRF flag to 0. The RDRF
flag is cleared automatically
when DMAC or DTC* is
activated by an RXI interrupt and
the RDR value is read.
Receive error processing and

Related parts for DF2214BQ16V