C8051F131R Silicon Labs, C8051F131R Datasheet - Page 278

no-image

C8051F131R

Manufacturer Part Number
C8051F131R
Description
8-bit Microcontrollers - MCU 128kB 100MIPS 8448B RAM
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051F131R

Product Category
8-bit Microcontrollers - MCU
Core
8051
Data Bus Width
8 bit
Maximum Clock Frequency
100 MHz
Program Memory Size
128 KB
Data Ram Size
8.25 KB
On-chip Adc
Yes
Operating Supply Voltage
2.7 V to 3.6 V
Package / Case
TQFP-64
Mounting Style
SMD/SMT
A/d Bit Size
10 bit
A/d Channels Available
9
Data Rom Size
64 KB
Interface Type
I2C, SMBus, SPI, UART
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
32
Number Of Timers
16 bit
Processor Series
C8051
Program Memory Type
Flash
Factory Pack Quantity
500
Supply Voltage - Max
3.6 V
Supply Voltage - Min
3 V
C8051F120/1/2/3/4/5/6/7
C8051F130/1/2/3
20.5. Serial Clock Timing
Four combinations of serial clock phase and polarity can be selected using the clock control bits in the
SPI0 Configuration Register (SPI0CFG). The CKPHA bit (SPI0CFG.5) selects one of two clock phases
(edge used to latch the data). The CKPOL bit (SPI0CFG.4) selects between an active-high or active-low
clock. Both master and slave devices must be configured to use the same clock phase and polarity. SPI0
should be disabled (by clearing the SPIEN bit, SPI0CN.0) when changing the clock phase or polarity. The
clock and data line relationships for master mode are shown in Figure 20.5. For slave mode, the clock and
data relationships are shown in Figure 20.6 and Figure 20.7. Note that CKPHA must be set to ‘0’ on both
the master and slave SPI when communicating between two of the following devices: C8051F04x,
C8051F06x, C8051F12x/13x, C8051F31x, C8051F32x, and C8051F33x
The SPI0 Clock Rate Register (SPI0CKR) as shown in SFR Definition 20.3 controls the master mode
serial clock frequency. This register is ignored when operating in slave mode. When the SPI is configured
as a master, the maximum data transfer rate (bits/sec) is one-half the system clock frequency or 12.5 MHz,
whichever is slower. When the SPI is configured as a slave, the maximum data transfer rate (bits/sec) for
full-duplex operation is 1/10 the system clock frequency, provided that the master issues SCK, NSS (in 4-
wire slave mode), and the serial input data synchronously with the slave’s system clock. If the master
issues SCK, NSS, and the serial input data asynchronously, the maximum data transfer rate (bits/sec)
must be less than 1/10 the system clock frequency. In the special case where the master only wants to
transmit data to the slave and does not need to receive data from the slave (i.e. half-duplex operation), the
SPI slave can receive data at a maximum data transfer rate (bits/sec) of 1/4 the system clock frequency.
This is provided that the master issues SCK, NSS, and the serial input data synchronously with the slave’s
system clock.
278
NSS (Must Remain High
in Multi-Master Mode)
SCK
(CKPOL=0, CKPHA=0)
SCK
(CKPOL=0, CKPHA=1)
SCK
(CKPOL=1, CKPHA=0)
SCK
(CKPOL=1, CKPHA=1)
MISO/MOSI
Figure 20.5. Master Mode Data/Clock Timing
MSB
Bit 6
Bit 5
Rev. 1.4
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0