TMP86xy92DMG Toshiba, TMP86xy92DMG Datasheet - Page 80

no-image

TMP86xy92DMG

Manufacturer Part Number
TMP86xy92DMG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP86xy92DMG

Package
SSOP30
Rom Types (m=mask,p=otp,f=flash)
M/F
Rom Size
16
Ram Size
512
Driver Led
8
Driver Lcd
-
Spi/sio Channels
1
Uart/sio Channels
2
I2c/sio Channels
1
High-speed Serial Output
-
Adc 8-bit Channels
-
Adc 10-bit Channels
6
Da Converter Channels
-
Timer Counter 18-bit Channel
-
Timer Counter 16-bit Channel
1
Timer Counter 8-bit Channel
2
Motor Channels
-
Watchdog Timer
Y
Dual Clock
Y
Clock Gear
-
Number Of I/o Ports
24
Power Supply (v)
4 to 5.5
7.3
Function
7.3
7.3.1
7.3.2
detection voltage, whether to enable or disable voltage detect operation and the action to be taken when the supply
voltage (VDD) falls to or below the detection voltage (VDxLVL) can be programmed by software.
Function
The voltage detecting circuit allows two detection voltage levels (VDxLVL, x = 1, 2) to be specified. For each
Immediately after release of a power-on reset,VDCR2<VDxEN>, is cleared to 0.
interrupt request signals. When VDCR2<VDxMOD> is set to "1", the operation mode is set to generate voltage
detection reset signals.
Enabling/Disabling Voltage Detection Operation
Selecting the Voltage Detect Operating Mode
Setting the VDCR2<VDxEN> bit to 1 enables voltage detect operation and clearing this bit to 0 disables it.
When VDCR2<VDxMOD> is set to "0", the voltage detection operation mode is set to generate INTVLTD
Note:Setting VDCR2<VDxEN> to 1 while the supply voltage is below the detection voltage (VDD<VDxLVL)
INTVLTD interruptrequest signal
Note:Since the comparators used for voltage detection do not have a hysteresis structure, INTVLTD interrupt
・ When the operation mode is set to generate INTVLTD interrupt signals (VDCR2<VDxMOD>="0")
・ When the operation mode is set to generate voltage detection reset signals (VDCR2<VDxMOD>="1")
immediately causes an INTVLTD interrupt or a voltage detect x reset signal to be generated.
voltage (VDD) falls to the detection voltage (VDxLVL).
request signals may be generated frequently when the supply voltage (VDD) is close to the detection
voltage (VDxLVL). INTVLTD interrupt request signals may be generated not only when the supply voltage
falls to the detection voltage but also when it rises to the detection voltage.
(VDD) becomes lower than the detection voltage (VDxLVL).
detection reset signal is generated continuously as long as the supply voltage (VDD) is lower than the
detection voltage (VDxLVL).
Voltage detection level
When VDCR2<VDxEN>="1", an INTVLTD interrupt request signal is generated when the supply
When VDCR2<VDxEN> = "1", a voltage detection reset signal is generated when the supply voltage
VDCR1 and VDCR2 are initialized by a power-on reset or an external reset input only. A voltage
VDCR2<VDEN>
Figure 7-2 Voltage Detection Interrupt Request
VDD level
Page 66
(Note)
(Note)
TMP86FH92DMG