HD6432646 Hitachi, HD6432646 Datasheet - Page 755

no-image

HD6432646

Manufacturer Part Number
HD6432646
Description
(HD64F264x Series) 16-Bit Microcomputer
Manufacturer
Hitachi
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B37FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B67FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B82FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646B99FCJ
Manufacturer:
MOT
Quantity:
44
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 954
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 700
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C64FCJ
Manufacturer:
RENESAS
Quantity:
1 500
Part Number:
HD6432646C90FCJV
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646D08FCJV
Manufacturer:
RENESAS
Quantity:
1 700
21.4
The PLL circuit has the function of multiplying the frequency of the clock from the oscillator by a
factor of 1, 2, or 4. The multiplication factor is set with the STC bits in SCKCR. The phase of the
rising edge of the internal clock is controlled so as to match that at the EXTAL pin. The clock
frequency before and after multiplication must not exceed the maximum operating frequency
range of this LSI.
When the multiplication factor of the PLL circuit is changed, the operation varies according to the
setting of the STCS bit in SCKCR.
When STCS = 0 (initial value), the setting becomes valid after a transition to software standby
mode, watch mode, or subactive mode. The transition time count is performed in accordance with
the setting of bits STS2 to STS0 in SBYCR.
[1] The initial PLL circuit multiplication factor is 1.
[2] A value is set in bits STS2 to STS0 to give the specified transition time.
[3] The target value is set in STC1 and STC0, and a transition is made to software standby mode,
[4] The clock pulse generator stops and the value set in STC1 and STC0 becomes valid.
[5] Software standby mode, watch mode, or subactive mode is cleared, and a transition time is
[6] After the set transition time has elapsed, the LSI resumes operation using the target
If a PC break is set for the SLEEP instruction that causes a transition to software standby mode in
[1], software standby mode is entered and break exception handling is executed after the
oscillation stabilization time. In this case, the instruction following the SLEEP instruction is
executed after execution of the RTE instruction.
When STCS = 1, the LSI operates on the changed multiplication factor immediately after bits
STC1 and STC0 are rewritten.
21.5
The medium-speed clock divider divides the system clock to generate ø/2, ø/4, ø/8, ø/16, and ø/32.
21.6
The bus master clock selection circuit selects the system clock (ø) or one of the medium-speed
clocks (ø/2, ø/4, or ø/8, ø/16, and ø/32) to be supplied to the bus master, according to the settings
of the SCK2 to SCK0 bits in SCKCR.
watch mode, or subactive mode.
secured in accordance with the setting in STS2 to STS0.
multiplication factor.
PLL Circuit
Medium-Speed Clock Divider
Bus Master Clock Selection Circuit