HD6432646 Hitachi, HD6432646 Datasheet - Page 522

no-image

HD6432646

Manufacturer Part Number
HD6432646
Description
(HD64F264x Series) 16-Bit Microcomputer
Manufacturer
Hitachi
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B37FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B67FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B82FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646B99FCJ
Manufacturer:
MOT
Quantity:
44
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 954
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 700
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C64FCJ
Manufacturer:
RENESAS
Quantity:
1 500
Part Number:
HD6432646C90FCJV
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646D08FCJV
Manufacturer:
RENESAS
Quantity:
1 700
13.4
The SCI has four interrupt sources: the transmit-end interrupt (TEI) request, receive-error interrupt
(ERI) request, receive-data-full interrupt (RXI) request, and transmit-data-empty interrupt (TXI)
request. Table 13-12 shows the interrupt sources and their relative priorities. Individual interrupt
sources can be enabled or disabled with the TIE, RIE, and TEIE bits in the SCR. Each kind of
interrupt request is sent to the interrupt controller independently.
When the TDRE flag in SSR is set to 1, a TXI interrupt request is generated. When the TEND flag
in SSR is set to 1, a TEI interrupt request is generated. A TXI interrupt can activate the DTC to
perform data transfer. The TDRE flag is cleared to 0 automatically when data transfer is
performed by the DTC. The DTC cannot be activated by a TEI interrupt request.
When the RDRF flag in SSR is set to 1, an RXI interrupt request is generated. When the ORER,
PER, or FER flag in SSR is set to 1, an ERI interrupt request is generated. An RXI interrupt can
activate the DTC to perform data transfer. The RDRF flag is cleared to 0 automatically when data
transfer is performed by the DTC. The DTC cannot be activated by an ERI interrupt request.
Table 13-12 SCI Interrupt Sources
Channel
0
1
2
(H8S/2648,
H8S/2648R,
H8S/2647)
Note: * This table shows the initial state immediately after a reset. Relative priorities among
488
channels can be changed by means of the interrupt controller.
SCI Interrupts
Interrupt
Source Description
ERI
RXI
TXI
TEI
ERI
RXI
TXI
TEI
ERI
RXI
TXI
TEI
Interrupt due to receive error (ORER, FER, or PER) Not possible
Interrupt due to receive data full state (RDRF)
Interrupt due to transmit data empty state (TDRE)
Interrupt due to transmission end (TEND)
Interrupt due to receive error (ORER, FER, or PER) Not possible
Interrupt due to receive data full state (RDRF)
Interrupt due to transmit data empty state (TDRE)
Interrupt due to transmission end (TEND)
Interrupt due to receive error (ORER, FER, or PER) Not possible
Interrupt due to receive data full state (RDRF)
Interrupt due to transmit data empty state (TDRE)
Interrupt due to transmission end (TEND)
DTC
Activation
Possible
Possible
Not possible
Possible
Possible
Not possible
Possible
Possible
Not possible
Priority*
High
Low

Related parts for HD6432646