HD6432646 Hitachi, HD6432646 Datasheet - Page 243

no-image

HD6432646

Manufacturer Part Number
HD6432646
Description
(HD64F264x Series) 16-Bit Microcomputer
Manufacturer
Hitachi
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B37FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B67FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B82FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646B99FCJ
Manufacturer:
MOT
Quantity:
44
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 954
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 700
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C64FCJ
Manufacturer:
RENESAS
Quantity:
1 500
Part Number:
HD6432646C90FCJV
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646D08FCJV
Manufacturer:
RENESAS
Quantity:
1 700
8.3.12
Normal Mode: An example is shown in which the DTC is used to receive 128 bytes of data via
the SCI.
[1] Set MRA to fixed source address (SM1 = SM0 = 0), incrementing destination address (DM1 =
[2] Set the start address of the register information at the DTC vector address.
[3] Set the corresponding bit in DTCER to 1.
[4] Set the SCI to the appropriate receive mode. Set the RIE bit in SCR to 1 to enable the reception
[5] Each time reception of one byte of data ends on the SCI, the RDRF flag in SSR is set to 1, an
[6] When CRA becomes 0 after the 128 data transfers have ended, the RDRF flag is held at 1, the
1, DM0 = 0), normal mode (MD1 = MD0 = 0), and byte size (Sz = 0). The DTS bit can have
any value. Set MRB for one data transfer by one interrupt (CHNE = 0, DISEL = 0). Set the
SCI RDR address in SAR, the start address of the RAM area where the data will be received in
DAR, and 128 (H'0080) in CRA. CRB can be set to any value.
complete (RXI) interrupt. Since the generation of a receive error during the SCI reception
operation will disable subsequent reception, the CPU should be enabled to accept receive error
interrupts.
RXI interrupt is generated, and the DTC is activated. The receive data is transferred from RDR
to RAM by the DTC. DAR is incremented and CRA is decremented. The RDRF flag is
automatically cleared to 0.
DTCE bit is cleared to 0, and an RXI interrupt request is sent to the CPU. The interrupt
handling routine should perform wrap-up processing.
Examples of Use of the DTC
209

Related parts for HD6432646