HD6432646 Hitachi, HD6432646 Datasheet - Page 713

no-image

HD6432646

Manufacturer Part Number
HD6432646
Description
(HD64F264x Series) 16-Bit Microcomputer
Manufacturer
Hitachi
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6432646A52FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B37FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B67FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646B82FCJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6432646B99FCJ
Manufacturer:
MOT
Quantity:
44
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646B99FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 954
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS
Quantity:
1 700
Part Number:
HD6432646C41FCJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6432646C64FCJ
Manufacturer:
RENESAS
Quantity:
1 500
Part Number:
HD6432646C90FCJV
Manufacturer:
RENESAS
Quantity:
3 967
Part Number:
HD6432646D08FCJV
Manufacturer:
RENESAS
Quantity:
1 700
Figure 20-9 shows the procedure for executing the program/erase control program when
transferred to on-chip RAM.
Note: * Do not apply a constant high level to the FWE pin. Apply a high level to the FWE pin
only when the flash memory is programmed or erased. Also, while a high level is
applied to the FWE pin, the watchdog timer should be activated to prevent
overprogramming or overerasing due to program runaway, etc.
For more information on FWE application/cancel, refer to section 20.13, Flash
Memory Programming and Erasing Precautions.
Figure 20-9 User Program Mode Execution Procedure
Write the FWE assessment program and
transfer program (and the program/erase
control program if necessary) beforehand
Branch to flash memory application
program (flash memory rewriting)
Branch to program/erase control
Transfer program/erase control
Execute program/erase control
MD2, MD1, MD0 = 110, 111
program in RAM area
program to RAM
FWE = high*
Clear FWE
Reset-start
program
679