PEF2256 INFINEON [Infineon Technologies AG], PEF2256 Datasheet - Page 385

no-image

PEF2256

Manufacturer Part Number
PEF2256
Description
E1/T1/J1 Framer and Line Interface Component for Long- and Short-Haul Applications
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEF2256EV2.1ES
Manufacturer:
HARRIS
Quantity:
101
Part Number:
PEF2256EV2.2
Manufacturer:
INFINEON
Quantity:
513
Part Number:
PEF2256EV2.2
Manufacturer:
LANTIQ
Quantity:
8 000
Part Number:
PEF2256H
Manufacturer:
infineon
Quantity:
6
Part Number:
PEF2256H V1.2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
PEF2256HV
Manufacturer:
INF
Quantity:
20 000
Part Number:
PEF2256HV2.1
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
PEF2256HV2.1
Quantity:
116
Part Number:
PEF2256HV2.2
Manufacturer:
INFINEON
Quantity:
672
Part Number:
PEF2256HV2.2
Manufacturer:
INFINEON
Quantity:
8 000
Part Number:
PEF2256HV2.2
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
PEF2256HV2.2
Quantity:
7
Pulse Count Recovery (Read/Write)
Value after reset: 00
PCR
PCR(7:0)
User’s Manual
Hardware Description
PCR7
7
Pulse Count Recovery
A LOS alarm (red alarm) is cleared if a pulse-density is detected in the
received bit stream. The number of pulses M which must occur in the
predefined PCD time interval is programmable by the PCR register
and can be calculated as follows:
M = N+1; with 0 N 255.
The time interval starts with the first detected pulse transition. With
every received pulse a counter is incremented and the actual counter
is compared to the contents of PCR register. If the pulse number
reaches or exceeds the PCR value the LOS alarm is reset otherwise
the alarm stays active. In this case the next detected pulse transition
starts a new time interval.
An additional loss-of-signal recovery condition is selected by register
LIM2.LOS1.
H
385
DS1.1, 2003-10-23
T1/J1 Registers
PEF 2256 H/E
PCR0
0
FALC
(39)
®
56

Related parts for PEF2256