TMP91xy16FG Toshiba, TMP91xy16FG Datasheet - Page 220

no-image

TMP91xy16FG

Manufacturer Part Number
TMP91xy16FG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP91xy16FG

Package
LQFP100
Rom Types(m=mask,p=otp, F=flash,e=eeprom)
Romless
Rom Combinations
Romless
Ram Combinations
Ramless
Architecture
16-bit CISC
Usb/spi Channels
-
Uart/sio Channels
1
I2c/sio Bus Channels
-
(s)dram Controller
1
Adc 10-bit Channel
-
Da Converter
-
Timer 8-bit Channel
4
Timer 16-bit Channel
-
Pwm 8-bit Channels
-
Pwm 16-bit Channels
-
Cs/wait Controller
4
Dual Clock
Y
Number Of I/o Ports
31
Power Supply Voltage(v)
2.7 to 3.6
Note: This register can’t read and modify and write, because <VLD0IN> bit have different means
VLDCR0
(0440H)
3.15.1
between write data and read data.
Bit symbol
Read/Write
After reset
Function
SFR
the interruption can be controlled by voltage compare result.
Voltage level detector are controlled 3 registers: VLDCR0, VLDCR1 and VLDCR2. And
It shows Figure 3.15.4 VLDCR0 register.
Voltage
detect
start flag
0: Disable
1: Enable
V0EN
7
0
R/W
Figure 3.15.4 VLD Mode Control 0 Register
Detect
level
select flag
0: 1.5 V
1: 1.4 V
LHSEL
more
less
6
0
VLD Mode Control Register 0
Interrupt
enable
flag
0: Disable
1: Enable
INT0EN
R/W
5
0
91C016-218
Detect
voltage
result and
clear write
0: Normal
1: Voltage
VLD0IN
low
R/W
4
0
VLD0 detector voltage setting
Detect voltage compare result (Only 0 data write OK)
Interrupt enable/disable
Detect voltage flag setting
Voltage detect start
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
11**
0
1
0
1
0
1
0
1
12 steps (LHSEL = 0) + 5 steps (LHSEL = 1)
V03
3
0
1.5 V (LHSEL = 0), 0.9 V (LHSEL = 1)
1.6 V (LHSEL = 0), 1.0 V (LHSEL = 1)
1.7 V (LHSEL = 0), 1.1 V (LHSEL = 1)
1.8 V (LHSEL = 0), 1.2 V (LHSEL = 1)
1.9 V (LHSEL = 0), 1.3 V (LHSEL = 1)
2.0 V (LHSEL = 0), 1.4 V (LHSEL = 1)
2.1 V (LHSEL = 0), − (LHSEL = 1)
2.2 V (LHSEL = 0), − (LHSEL = 1)
2.3 V (LHSEL = 0), − (LHSEL = 1)
2.4 V (LHSEL = 0), − (LHSEL = 1)
2.5 V (LHSEL = 0), − (LHSEL = 1)
2.6 V (LHSEL = 0), − (LHSEL = 1)
Input voltage > Detect voltage
Input voltage < Detect voltage
Interrupt disable
Interrupt enable
Detect voltage area 1.5 V to 2.6 V
Detect voltage area 0.9 V to 1.4 V
Voltage compare turn off
Voltage compare turn on
Detect Level setting register
− (LHSEL = 0), − (LHSEL = 1)
V02
2
0
00H to 0BH
= 18 steps
R/W
V01
1
0
TMP91C016
V00
2008-02-20
0
0

Related parts for TMP91xy16FG