92
®
Power Unit Sensor
The power unit sensor indicates the status of the onboard power subsystem. If the power
subsystem fails to turn on the payload power, as indicated by the power unit power good
signal, a soft power control failure will be indicated. If the power unit power good signal is
deasserted after power has been successfully turned on, a power unit failure will be
indicated. This sensor is an IPMI sensor type Power Unit (09h).
states/offsets and its descriptions.
Power unit status sensor states
When a power fault has been detected, the contents of the CPLD "Power Fault1" and
"Power Fault2" registers are read and are stored as event data 2 (power fault 1
register) and event data 3 (power fault 1 register ) bytes in the SEL. The contents of
the event data are described in
Power unit status sensor event data
State
Power Off/Down
Power Cycle
Soft Power Control
Failure
Power Unit Failure
detected
Event Data
02h
03h
MPCBL0050 Single Board Computer
Bit
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7
Assertion /
Deassertion
Assertion and
Deassertion
Assertion and
Deassertion
Assertion
Assertion
Description
1_2V_E_PHY Power Fault
1_8V_E_PHY Power Fault
1_5V_E_ESB Power Fault
12V_E Power Fault
5V Power Fault
3_3V Power Fault
1_2V_SAS Power Fault
1_5V_ESB Power Fault
1_5V_DDR Power Fault
1_8V_DDR Power Fault
0.9VTT Power Fault
1_2VTT Power Fault
CPU0_VRM Power fault
CPU1_VRM Power fault
0
0
Table
Sensor-
specific
Offset
00h
01h
05h
06h
30.
Description
Asserted when system power is off, Deasserted when
power is on
Asserted and then deasserted as a result of a Power
Cycle request.
Power Cycle condition is the situation when power is
turned off, then immediately turned on.
Asserted if power unit did not respond to request to
turn on
Asserted if power unit changes power state
unexpectedly
MPCBL0050—Hardware Management
Table 29
Order Number: 318146-001
describes sensor
September 2007