Warning and error messages (Sheet 8 of 11)
E764
E765
E766
E767
E768
E769
E770
E772
E773
E774
E775
E776
E777
E778
Number
Cannot perform an SDR update with a
pending staged firmware image. Please
cancel the staged update, or use
--force-sdr-update or --no-reset.
IPMI error when trying to contact the
carrier board for the proxied target.
Cannot perform requested operations
against the requested target. The
target's carrier board is in firmware
transfer mode, and cannot forward
requests.
A timeout occurred waiting for the
target management controller to reset.
Error performing the requested
operation
Requested operation not supported on
the target.
IPMI error during a Get Device Id
transfer.
IPMI error during a Staged Get
Capabilities transfer.
IPMI error during a Staged Get Version
Data transfer.
No valid staging or rollback images were
found to register. Aborting.
Cannot perform a full FRU upgrade
without specifying --force-fru-update.
Performing a full FRU update will
overwrite all data stored in the FRU such
as serial numbers, part numbers,
manufacture date, etc. Please supply a
.cfg file name to perform an incremental
FRU update.
Cannot downgrade the FRU from version
%1 to version %2 without the --force-
fru-update flag.
Cannot compare FRU Product ID.
System FRU Product ID is missing.
Use --force-id flag to update
Cannot downgrade the SDR from
version %1 to version %2 without the
--force-sdr-update flag.
Message
If there is a pending staged firmware update, it is not
possible to perform an SDR update that would reset
the target. If the target were to reset after the SDR
update (which is the default behavior), then the FW
version would change also. To do the SDR update,
either commit the pending firmware update by
resetting the target, or prevent target reset after the
SDR update with the --no-reset flag, or else give the
--force-sdr-update flag to show that the pending
firmware update should be committed at the same
time.
Before communicating with a sub-FRU such as an RTM
or AMC, the carrier board (for example, an SBC) must
be queried to see if it is in a mode that would prevent
sub-FRU communication. This message is displayed if
there is a timeout to this query.
If a carrier board is in firmware transfer mode, then
none of its sub-FRUs are contactable. It is not possible,
for example, to update RTM firmware while its carrier is
busy in firmware transfer mode.
After sbcupdate resets a target, it waits until the target
is able to respond to a get device ID and the response
indicates the target is no longer in firmware transfer
mode.
An operation failed with an unknown error. This is a
generic catch-all and should not be displayed in
practice.
A user attempted to get a type of information (for
example, FRU, SDR, etc.) from a target that does not
support that type.
A non-successful completion code was returned for a
Get Device ID command request.
A non-successful completion code was returned for a
Staged Get Capabilities command request.
A non-successful completion code was returned for a
Staged Get Version command request.
A user attempted to use the rollback mode when there
was no valid staged or rollback firmware image
available.
This error message is displayed when a full FRU update
is attempted without specifying the force flag on the
command line. It also briefly states the impact of a full
FRU update.
This error message is displayed on a FRU downgrade
attempt without the force flag. The FRU downgrade
attempt explicitly requires the –-force-fru-update flag.
This error message is displayed when the Product ID
information in the existing system FRU is missing. Due
to this, the Product ID in the supplied input FRU file
and system FRU cannot be compared.
This error message is displayed on an SDR downgrade
attempt without the force flag. The SDR downgrade
attempt explicitly requires the –force-sdr-update flag.