Specifications of MPCBL0050N02Q

Lead Free Status / RoHS Status
Supplier Unconfirmed
10.6.7.3
10.6.7.4
Intel NetStructure
Technical Product Specification
202
®
Direct Firmware Update via RMCP Bridging
For RMCP bridging to work correctly, the Shelf Manager must be connected to the
network so that it can transmit TCP/IP traffic to and from the client. The interface
option must also be set to lan for RMCP bridging.
When using the sbcupdate utility over an RMCP bridge with the Intel NetStructure
MPCMM0001/0002 Chassis Management Module:
When using the sbcupdate utility over an RMCP bridge with a 3rd party Shelf Manager,
it is essential that communication between the target IPMC and a remote network node
via a shelf manager can be established. Refer to
privileges for RMCP bridging” on page 190
commands that must be forwarded to IPMB by the Shelf Manager.
The syntax of the command is:
An example command for direct firmware update via RMCP bridging is:
Direct Firmware Update to RTM via RMCP Bridging
To perform a direct firmware update to an RTM via RMCP bridging, you must add the
RTM to your target along with the target blade.
For RMCP bridging to work correctly, the Shelf Manager must be connected to the
network so that it can transmit TCP/IP traffic to and from the client. The interface
option must also be set to lan for RMCP bridging.
When using the sbcupdate utility over an RMCP bridge with the Intel NetStructure
MPCMM0001/0002 Chassis Management Module:
When using the sbcupdate utility over an RMCP bridge with a 3rd party Shelf Manager,
it is essential that communication between the target IPMC and a remote network node
via a shelf manager can be established. Refer to
privileges for RMCP bridging” on page 190
commands that must be forwarded to IPMB by the Shelf Manager.
The syntax of the command is:
• Check for a CMM firmware version of 6.1.1.x or higher.
• Transfer the /usr/share/doc/sbcutils/cmdPrivilege.ini file to both the active and
• Check for a CMM firmware version of 6.1.1.x or higher.
• Transfer the /usr/share/doc/sbcutils/cmdPrivilege.ini file to both the active and
MPCBL0050 Single Board Computer
standby CMMs. Place cmdPrivelege.ini in the /etc/ directory on the CMMs. Then,
restart the RMCP servers. More details on this can be found in
“Configuring the Intel NetStructure
standby CMMs. Place cmdPrivelege.ini in the /etc/ directory on the CMMs. Then,
restart the RMCP servers. More details on this can be found in
“Configuring the Intel NetStructure
# sbcupdate -I lan -M direct -H <shelf_manager_ip_address>
# sbcupdate -I lan -M direct -H 10.90.90.91 -U root
# sbcupdate -I lan -M direct -H <shelf_manager_ip_address>
-U <RMCP_username> -P <RMCP_password>
-t <target_blade>:rtm <path to RTM firmware image/filename>
-U <RMCP_username> -P <RMCP_password> -t <target>
<path to firmware image/filename>
-P cmmrootpass -t 0x8e MPCBL0050_FW_NNNNNN.hex
®
®
MPCMM0001/0002 CMM” on page
MPCMM0001/0002 CMM” on page
for more information on the required RMCP
for more information on the required RMCP
Table 74, “Required IPMI command
Table 74, “Required IPMI command
MPCBL0050—Firmware Update Utilities
Order Number: 318146-001
Section 10.5.2,
Section 10.5.2,
September 2007
191.
191.
®
®