MPCBL0050N02Q Intel, MPCBL0050N02Q Datasheet - Page 60

no-image

MPCBL0050N02Q

Manufacturer Part Number
MPCBL0050N02Q
Description
Manufacturer
Intel
Datasheet

Specifications of MPCBL0050N02Q

Lead Free Status / RoHS Status
Supplier Unconfirmed
4.3
Note:
Note:
4.4
Caution:
Figure 22.
Intel NetStructure
Technical Product Specification
60
®
AdvancedMC Module Installation
Install the AdvancedMC module as follows:
AdvancedMC modules must be installed before the board payload powers on or after
the operating system has fully loaded. If an AdvancedMC module is hot added after the
initial EFI BIOS device discovery, but before the operating system is fully loaded, then
the AdvancedMC module may not work properly and the SBC may stop booting. To
correct this, a board payload reset or payload power cycle is required.
AdvancedMC modules are not included with the MPCBL0050 board and must be
purchased separately. Refer to the MPCBL0050 Compatibility Report for a list of devices
validated.
AdvancedMC Filler Panels
AdvancedMC* filler panels are used to optimize cooling and reduce radiated emissions
when AdvancedMC modules are not installed in theMPCBL0050 AdvancedMC module
slots.
Do not operate the MPCBL0050 without filler panels or AdvancedMC modules installed.
AdvancedMC module slots should not be left open or uncovered when the MPCBL0050
is in use.
AdvancedMC filler panel
1. Install AdvancedMC module prior to board payload power-on or after the operating
2. Remove the AdvancedMC filler panel by pulling on the ejector handle until the
3. Insert the AdvancedMC module into the slot and close the ejector handle by
MPCBL0050 Single Board Computer
system is fully loaded.
module is removed.
pushing it toward the faceplate of the board.
MPCBL0050—Operating the Unit
5441-01
Order Number: 318146-001
September 2007