MPCBL0050N02Q Intel, MPCBL0050N02Q Datasheet - Page 203

no-image

MPCBL0050N02Q

Manufacturer Part Number
MPCBL0050N02Q
Description
Manufacturer
Intel
Datasheet

Specifications of MPCBL0050N02Q

Lead Free Status / RoHS Status
Supplier Unconfirmed
Firmware Update Utilities—MPCBL0050
10.6.8
10.6.8.1
Note:
September 2007
Order Number: 318146-001
An example of a command for direct firmware update to RTM via RMCP bridging is:
Staged Firmware Update
Staged Firmware Update Using KCS Interface
The staged firmware update mode allows the option of creating a backup copy of the
current operational image into a rollback partition area of flash memory, and then
writes the new operational firmware image to a staging area of flash memory. This
process happens while the IPMC is running normally. After completion of a staged
update, the IPMC resets automatically and the new firmware is loaded to the IPMC
(unless the -noreset-mmc option is used).
To perform a staged firmware update over the KCS interface, you must be logged into
the target SBC as root.
The syntax of the command is:
An example of a staged mode update is:
The output from this command should be similar to the following:
Entering Staged Firmware Update mode.
Preparing the staging flash area.
Staging flash area preparation complete.
Capturing the rollback image.
Rollback image captured successfully.
Uploading the new stage firmware image to the staging area.
0% completed
10% completed
20% completed
30% completed
40% completed
50% completed
60% completed
70% completed
80% completed
90% completed
100% completed
New staged image successfully uploaded.
Registering the staged firmware update in flash.
Staged firmware update successfully registered in flash.
The target management controller is being reset.
sbcupdate (W606) Please ignore any select timeout warnings.
linux diver due to the target reset, and may be ignored.
IPMI message handler: BMC returned incorrect response, expected netfn 7 cmd 2, got
netfn31 cmd a2
The target management controller has been reset.
Staged Firmware Update complete!
Program exiting!
The “IPMI message handler: BMC returned incorrect response.” error message is to be
expected and may be ignored. This is a timeout error in response to warning (W606) as
seen in the output above.
# sbcupdate -I lan -M direct -H 10.90.90.91 -U root
# sbcupdate -I kcs -M staged <path to firmware image/filename>
# sbcupdate -I kcs -M staged MPCBL0050_FW_NNNNNN.hex
-P cmmrootpass -t 0x8e:rtm MPRTM0050_NNNNNN.hex
Intel NetStructure
®
MPCBL0050 Single Board Computer
Technical Product Specification
They are issued by the