13.5 Smart Card FIFO Control Register (SCFR, write only at "base address + 2")
This register is used to control the FIFO functions of Smart Card interface.
Bit 6, 7:These two bits are used to set the active level for the receiver FIFO interrupt. For example, if
Bit 5 - 3:Reserved.
Bit 2: Setting this bit to a logical 1 resets the TX FIFO counter logic to initial state. This bit will be
Bit 1: Setting this bit to a logical 1 resets the RX FIFO counter logic to initial state. This bit will be
Bit 0: This bit enables FIFO of Smart Card interface. This bit should be set to a logical 1 before other
BIT 7
the interrupt active level is set as 4 bytes, once there are more than 4 data characters in the
receiver FIFO, the interrupt will be activated to notify the CPU to read the data from the FIFO.
cleared to a logical 0 by itself after being set to a logical 1.
cleared to a logical 0 by itself after being set to a logical 1.
bits of SCFR are programmed.
0
0
1
1
7
6
BIT 6
5
0
1
0
1
4
3
2
FIFO TRIGGER LEVEL
1
0
RX FIFO INTERRUPT ACTIVE LEVEL (BYTES)