W83627SF-AW Winbond, W83627SF-AW Datasheet - Page 44

no-image

W83627SF-AW

Manufacturer Part Number
W83627SF-AW
Description
Manufacturer
Winbond
Datasheet

Specifications of W83627SF-AW

Pin Count
128
Lead Free Status / RoHS Status
Not Compliant
7.1.7 Bank0.Reg6 - Remote Infrared Config Register (RIR_CFG)
Power on default <7:0> = 0000,0000 binary
BIT
7-6
5-4
3-2
1
0
RXDMSL<1:0>
SMPSEL<1:0>
LP_SL<1:0>
PRE_DIV
RXINV
NAME
READ/WRITE
Read/Write
Read/Write
Read/Write
Read/Write
Read/Write
Sampling
methodology from the internal filter. Selected decoder
mode will determine the receive data format. The
sampling mode is shown as bellow:
SMPSEL<1:0> = 00 T-Period Sample Mode.
SMPSEL<1:0> = 01 Over-Sampling Mode.
SMPSEL<1:0> = 10 Over-Sampling with re-sync.
SMPSEL<1:0> = 11 FIFO Test Mode.
The T-period code format is defined as follows.
The Bit value is set to 0, then the high pulse will be
received. The Bit value is set to 1, then no energy will
be received. The opposite results will be generated
when the bit RXINV (Bank0.Reg6.Bit0) is set to 1.
Low pass filter source selection.
LP_SL<1:0> = 00 Select raw IRRX signal.
LP_SL<1:0> = 01 Select R.B.P. signal
LP_SL<1:0> = 10 Select D.B.P. signal.
LP_SL<1:0> = 11 Reserved.
Receiver Demodulation Source Selection.
RXDMSL<1:0> = 00 select B.P. and L.P. filter.
RXDMSL<1:0> = 01 select B.P. but not L.P.
RXDMSL<1:0> = 10 Reserved.
RXDMSL<1:0> = 11 do not pass demodulation.
Baud Rate Pre-divisor. Set to 1, the baud rate generator
input clock is set to 1.8432M Hz which is set to pre-
divisor into 13. When set to 0, the pre-divisor is set to 1,
that is, the input clock of baud rate generator is set to
24M Hz.
Receiving Signal Invert. Write to 1, Invert the receiving
signal.
B7 B6 B5 B4
-44-
Bit value
Mode
(Number of bits) - 1
Select.
DESCRIPTION
B3
B2 B1 B0
Select
internal
W83627SF
decoder