ATEVK1104 Atmel, ATEVK1104 Datasheet - Page 807

KIT DEV/EVAL FOR AVR32 AT32UC3A

ATEVK1104

Manufacturer Part Number
ATEVK1104
Description
KIT DEV/EVAL FOR AVR32 AT32UC3A
Manufacturer
Atmel
Series
AVR®32r
Type
MCUr
Datasheets

Specifications of ATEVK1104

Contents
Evaluation Board, Software and Documentation
Processor To Be Evaluated
AT32UC3A3
Data Bus Width
32 bit
Interface Type
USB, SPI, USART
Silicon Manufacturer
Atmel
Core Architecture
AVR
Core Sub-architecture
AVR UC3
Silicon Core Number
AT32UC3A3256
Silicon Family Name
AVR
Kit Contents
Board CD Docs
Rohs Compliant
Yes
For Use With/related Products
AT32UC3A3
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATEVK1104
Manufacturer:
Atmel
Quantity:
135
41.5
41.5.1
32058J–AVR32–04/11
Rev. E
SPI
1. SPI FDIV option does not work
2. SPI Slave / PDCA transfer: no TX UNDERRUN flag
3. SPI Bad serial clock generation on 2nd chip select when SCBR=1, CPOL=1 and
4. SPI Glitch on RXREADY flag in slave mode when enabling the SPI or during the first
5. SPI CSNAAT bit 2 in register CSR0...CSR3 is not available.
6. SPI disable does not work in SLAVE mode.
7. SPI Bad Serial Clock Generation on 2nd chip_select when SCBR = 1, CPOL=1 and
Selecting clock signal using FDIV = 1 does not work as specified.
Fix/Workaround
Do not set FDIV = 1.
There is no TX UNDERRUN flag available, therefore in SPI slave mode, there is no way to
be informed of a character lost in transmission.
Fix/Workaround
For PDCA transfer: none.
CNCPHA=0
When multiple CS are in use, if one of the baudrate equals to 1 and one of the others
doesn’t equal to 1, and CPOL=1 and CPHA=0, then an additional pulse will be generated on
SCK.
Fix/Workaround
When multiple CS are in use, if one of the baudrate equals to 1, the other must also equal 1
if CPOL=1 and CPHA=0.
transfer
In slave mode, the SPI can generate a false RXREADY signal during enabling of the SPI or
during the first transfer.
Fix/Workaround
1. Set slave mode, set required CPOL/CPHA.
2. Enable SPI.
3. Set the polarity CPOL of the line in the opposite value of the required one.
4. Set the polarity CPOL to the required one.
5. Read the RXHOLDING register.
Transfers can now befin and RXREADY will now behave as expected.
Fix/Workaround
Do not use this bit.
Fix/Workaround
Read the last received data, then perform a Software Reset.
NCPHA=0
When multiple CS are in use, if one of the baudrate equals to 1 and one of the others doesn't
equal to 1, and CPOL=1 and CPHA=0, then an aditional pulse will be generated on SCK.
807

Related parts for ATEVK1104