st92f124 STMicroelectronics, st92f124 Datasheet - Page 411

no-image

st92f124

Manufacturer Part Number
st92f124
Description
8/16-bit Single Voltage Flash Mcu Family With Ram, E3 Tmemulated Eeprom, Can 2.0b And J1850 Blpd
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
st92f124R9T6
Manufacturer:
ST
0
Part Number:
st92f124R9TB
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
st92f124R9TB
Manufacturer:
ST
0
Part Number:
st92f124V1QB
Manufacturer:
MAXIM
Quantity:
56
Part Number:
st92f124V1QB
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
st92f124V1QB
Manufacturer:
ST
0
Part Number:
st92f124V1QB
Manufacturer:
ST
Quantity:
20 000
Part Number:
st92f124V1T6
Manufacturer:
MAX
Quantity:
62
Part Number:
st92f124V1T6
Manufacturer:
ST
Quantity:
20 000
Part Number:
st92f124VQB
Manufacturer:
ST
Quantity:
1 831
KNOWN LIMITATIONS (Cont’d)
13.1.3.3 AF bit (acknowledge failure flag) in
transmitter mode (slave and master)
Description
The AF bit is cleared by reading the I2CSR2 reg-
ister. However, if read before the completion of the
transmission, the AF flag will be set again, thus
possibly generating a new interrupt.
Workaround
Software must ensure either that the SCL line is
back at 0 before reading the SR2 register, or be
able to correctly handle a second interrupt during
the 9th pulse of a transmitted byte.
13.1.3.4 BUSY flag in multimaster mode
Description
The BUSY flag is NOT updated when the interface
is disabled (PE=0). This can have consequences
when operating in Multimaster mode; i.e. a second
active I2C master commencing a transfer with an
unset BUSY bit can cause a conflict resulting in
lost data.
Workaround
Check that the I2C is not busy before enabling the
I2C Multimaster cell.
ST92F124/F150/F250 - KNOWN LIMITATIONS
13.1.3.5
multimaster mode
Description
In a Multimaster environment, when the interface
is configured in Master Receive mode it does not
perform arbitration during the reception of the Ac-
knowledge Bit. Mishandling of the ARLO bit from
the I2CSR2 register may occur when a second
master simultaneously requests the same data
from the same slave and the I2C master does not
acknowledge the data. The ARLO bit is then left at
0 instead of being set.
Workaround
None
13.1.3.6 BUSY flag gets cleared when BUS
error occurs
Description
BUSY bit gets cleared when the BUS error occurs
but the bus is actually BUSY (SCL line shows CLK
pulses). Contradictory, M/SL bit is unaffected on
BUS error
Workaround
If a Bus Error occurs, a Stop or a repeated Start
condition should be generated by the Master to re-
synchronize communication, get the transmission
acknowledged and the bus released for further
communication
ARLO
(arbitration
lost)
flag
411/426