st92f124 STMicroelectronics, st92f124 Datasheet - Page 105

no-image

st92f124

Manufacturer Part Number
st92f124
Description
8/16-bit Single Voltage Flash Mcu Family With Ram, E3 Tmemulated Eeprom, Can 2.0b And J1850 Blpd
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
st92f124R9T6
Manufacturer:
ST
0
Part Number:
st92f124R9TB
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
st92f124R9TB
Manufacturer:
ST
0
Part Number:
st92f124V1QB
Manufacturer:
MAXIM
Quantity:
56
Part Number:
st92f124V1QB
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
st92f124V1QB
Manufacturer:
ST
0
Part Number:
st92f124V1QB
Manufacturer:
ST
Quantity:
20 000
Part Number:
st92f124V1T6
Manufacturer:
MAX
Quantity:
62
Part Number:
st92f124V1T6
Manufacturer:
ST
Quantity:
20 000
Part Number:
st92f124VQB
Manufacturer:
ST
Quantity:
1 831
5.11 INTERRUPT REGISTERS
CENTRAL INTERRUPT CONTROL REGISTER
(CICR)
R230 - Read/Write
Register Group: System
Reset value: 1000 0111 (87h)
Bit 7 = GCEN: Global Counter Enable.
This bit enables the 16-bit Multifunction Timer pe-
ripheral.
0: MFT disabled
1: MFT enabled
Bit 6 = TLIP: Top Level Interrupt Pending.
This bit is set by hardware when Top Level Inter-
rupt (TLI) trigger event occurs. It is cleared by
hardware when a TLI is acknowledged. It can also
be set by software to implement a software TLI.
0: No TLI pending
1: TLI pending
Bit 5 = TLI: Top Level Interrupt.
This bit is set and cleared by software.
0: A Top Level Interrupt is generared when TLIP is
1: A Top Level Interrupt request is generated when
Bit 4 = IEN: Interrupt Enable.
This bit is cleared by the interrupt machine cycle
(except for a TLI).
It is set by the iret instruction (except for a return
from TLI).
It is set by the EI instruction.
It is cleared by the DI instruction.
0: Maskable interrupts disabled
1: Maskable Interrupts enabled
Note: The IEN bit can also be changed by soft-
ware using any instruction that operates on regis-
ter CICR, however in this case, take care to avoid
spurious interrupts, since IEN cannot be cleared in
the middle of an interrupt arbitration. Only modify
GCEN TLIP
set, only if TLNM=1 in the NICR register (inde-
pendently of the value of the IEN bit).
IEN=1 and the TLIP bit are set.
7
TLI
IEN
IAM CPL2 CPL1 CPL0
0
the IEN bit when interrupts are disabled or when
no peripheral can generate interrupts. For exam-
ple, if the state of IEN is not known in advance,
and its value must be restored from a previous
push of CICR on the stack, use the sequence DI;
POP CICR to make sure that no interrupts are be-
ing arbitrated when CICR is modified.
Bit 3 = IAM: Interrupt Arbitration Mode.
This bit is set and cleared by software.
0: Concurrent Mode
1: Nested Mode
Bits 2:0 = CPL[2:0]: Current Priority Level.
These bits define the Current Priority Level.
CPL=0 is the highest priority. CPL=7 is the lowest
priority. These bits may be modified directly by the
interrupt hardware when Nested Interrupt Mode is
used.
EXTERNAL INTERRUPT TRIGGER REGISTER
(EITR)
R242 - Read/Write
Register Page: 0
Reset value: 0000 0000 (00h)
Bit 7 = TED1: INTD1 Trigger Event
Bit 6 = TED0: INTD0 Trigger Event
Bit 5 = TEC1: INTC1 Trigger Event
Bit 4 = TEC0: INTC0 Trigger Event
Bit 3 = TEB1: INTB1 Trigger Event
Bit 2 = TEB0: INTB0 Trigger Event
Bit 1 = TEA1: INTA1 Trigger Event
Bit 0 = TEA0: INTA0 Trigger Event
These bits are set and cleared by software.
0: Select falling edge as interrupt trigger event
1: Select rising edge as interrupt trigger event
TED1 TED0 TEC1 TEC0 TEB1 TEB0 TEA1 TEA0
7
ST92F124/F150/F250 - INTERRUPTS
105/426
0
9

Related parts for st92f124