pef2256e Infineon Technologies Corporation, pef2256e Datasheet - Page 156

no-image

pef2256e

Manufacturer Part Number
pef2256e
Description
E1/t1/j1 Framer And Line Interface Component For Long- And Short-haul Applications
Manufacturer
Infineon Technologies Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
pef2256eV2.1ES
Manufacturer:
HARRIS
Quantity:
101
Part Number:
pef2256eV2.2
Manufacturer:
INFINEON
Quantity:
513
Part Number:
pef2256eV2.2
Manufacturer:
LANTIQ
Quantity:
8 000
Table 39
Alarm
Yellow Alarm or
Remote Alarm
(RRA)
Excessive Zeros
(EXZD)
Pulse-Density
Violation
(PDEN)
Transmit Line
Short
(XLS)
Transmit
Ones-Density
(XLO)
1)
5.3.2
User’s Manual
Hardware Description
RRA detection operates in the presence of 10
Automatic remote alarm (Yellow Alarm) access
If the receiver has lost its synchronization (FRS0.LFA) a remote alarm (yellow alarm)
is sent to the distant end automatically, if enabled by bit FMR2.AXRA. In synchronous
state the remote alarm bit is removed.
Automatic AIS to system interface
In asynchronous state the synchronizer enforces an AIS to the receive system
1)
Auto Modes
Summary of Alarm Detection and Release (T1/J1) (cont’d)
Detection Condition
RC1.RRAM = 0:
bit 2 = 0 in 255 consecutive time
slots or
FS-bit = 1 of frame12 in F12 (D4)
format or
8× 1,8× 0 in the DL channel
(ESF)
RC1.RRAM = 1:
bit 2 = 0 in every time slot per
frame or
FS-bit = 1 of frame12 in F12 (D4)
format or
8× 1,8× 0 in the DL channel
(ESF)
more than 7 (B8ZS code) or
more than 15 (AMI code)
contiguous zeros
less than N ones in each and
every time window of 8× (N+1)
time slots with N taking all values
of 1 to 23
or
more than 15 consecutive zeros
more than 3 pulse periods with
highly increased transmit line
current on XL1/2
32 consecutive zeros in the
transmit data stream on XL1/2
-3
bit error rate.
156
Clear Condition
RC1.RRAM = 0:
set conditions no longer detected.
RC1.RRAM = 1:
bit 2 = 0 not detected in 3
consecutive frames or
FS-bit not detected in 3
consecutive multiframes or
8× 1,8× 0 not detected for 3 times
in a row (ESF).
Latched Status: cleared on read
Latched Status: cleared on read
transmit line current limiter
inactive
Cleared with each transmitted
pulse
Functional Description T1/J1
DS1.1, 2003-10-23
PEF 2256 H/E
FALC
®
56

Related parts for pef2256e