MC68HC908AS60CFN Freescale Semiconductor, MC68HC908AS60CFN Datasheet - Page 355

no-image

MC68HC908AS60CFN

Manufacturer Part Number
MC68HC908AS60CFN
Description
IC MCU 60K FLASH 8MHZ 52-PLCC
Manufacturer
Freescale Semiconductor
Series
HC08r
Datasheet

Specifications of MC68HC908AS60CFN

Core Processor
HC08
Core Size
8-Bit
Speed
8.4MHz
Connectivity
SCI, SPI
Peripherals
LVD, POR, PWM
Number Of I /o
40
Program Memory Size
60KB (60K x 8)
Program Memory Type
FLASH
Eeprom Size
1K x 8
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 15x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
52-PLCC
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68HC908AS60CFN
Manufacturer:
MOT
Quantity:
5 510
Part Number:
MC68HC908AS60CFN
Manufacturer:
TI
Quantity:
5 510
Part Number:
MC68HC908AS60CFN
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
MC68HC908AS60 — Rev. 1.0
CRC Error
Symbol Error
Framing Error
Bus Fault
A cyclical redundancy check (CRC) error is detected when the data
bytes and CRC byte of a received message are processed and the
CRC calculation result is not equal. The CRC code will detect any
single and 2-bit errors, as well as all 8-bit burst errors and almost all
other types of errors. The CRC error flag (in BSVR) is set when a CRC
error is detected (see
A symbol error is detected when an abnormal (invalid) symbol is
detected in a message being received from the J1850 bus. The invalid
symbol is set when a symbol error is detected (see
State Vector
A framing error is detected if an EOD or EOF symbol is detected on a
non-byte boundary from the J1850 bus. A framing error also is
detected if the BDLC is transmitting the EOD and instead receives an
active symbol. The symbol invalid, or the out-of-range flag, is set
when a framing error is detected (see
Register).
If a bus fault occurs, the response of the BDLC will depend upon the
type of bus fault.
If the bus is shorted to battery, the BDLC will wait for the bus to fall to
a passive state before it will attempt to transmit a message. As long
as the short remains, the BDLC will never attempt to transmit a
message onto the J1850 bus.
If the bus is shorted to ground, the BDLC will see an idle bus, begin
to transmit the message, and then detect a transmission error (in
BSVR), since the short to ground would not allow the bus to be driven
to the active (dominant) SOF state. The BDLC will abort that
transmission and wait for the next CPU command to transmit.
Freescale Semiconductor, Inc.
For More Information On This Product,
Byte Data Link Controller-Digital (BDLC-D)
Go to: www.freescale.com
Register).
21.7.4 BDLC State Vector
Byte Data Link Controller-Digital (BDLC-D)
21.7.4 BDLC State Vector
BDLC Protocol Handler
Register).
21.7.4 BDLC
Technical Data

Related parts for MC68HC908AS60CFN