Specifications of DF2148RTE20IV

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
Host Interface, I²C, IrDA, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
74
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
4 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Section 11 16-Bit Free-Running Timer
Bit 4—Input Capture Flag D (ICFD): This status flag indicates that the FRC value has been
transferred to ICRD by means of an input capture signal. When BUFEB = 1, on occurrence of the
signal transition in FTID (input capture signal) specified by the IEDGD bit, ICFD is set but data is
not transferred to ICRD. Therefore, in buffer operation, ICFD can be used as an external interrupt
by setting the ICIDE bit to 1.
ICFD must be cleared by software. It is set by hardware, however, and cannot be set by software.
Bit 4
ICFD
0
1
Bit 3—Output Compare Flag A (OCFA): This status flag indicates that the FRC value matches
the OCRA value. This flag must be cleared by software. It is set by hardware, however, and
cannot be set by software.
Bit 3
OCFA
0
1
Bit 2—Output Compare Flag B (OCFB): This status flag indicates that the FRC value matches
the OCRB value. This flag must be cleared by software. It is set by hardware, however, and cannot
be set by software.
Bit 2
OCFB
0
1
Rev. 4.00 Sep 27, 2006 page 318 of 1130
REJ09B0327-0400
Description
[Clearing condition]
Read ICFD when ICFD = 1, then write 0 in ICFD
[Setting condition]
When an input capture signal is received
Description
[Clearing condition]
Read OCFA when OCFA = 1, then write 0 in OCFA
[Setting condition]
When FRC = OCRA
Description
[Clearing condition]
Read OCFB when OCFB = 1, then write 0 in OCFB
[Setting condition]
When FRC = OCRB
(Initial value)
(Initial value)
(Initial value)