This appendix provides easy reference to the words in PLC memory areas used by Controller Link Networks.
CS/CJ-series PLCs
Auxiliary Area
Network Status Flags
Bits A20200 through A20207 are turned ON to indicate that ports #0 through #7, respectively, are enabled for
the SEND(90), RECV(98), CMND(490) and PMCR. Bits A219200 through A219207 are turned ON to indicate
that an error has occurred in ports #0 through #7, respectively, during data communications using SEND(90),
RECV(98), CMND(490), or PMCR. Refer to page 192.
A203 through A210 contain the completion codes for ports #0 through #7, respectively, following data commu-
nications using SEND(90), RECV(98), CMND(490), or PMCR. Refer to page 192.
CS/CJ CPU Bus Unit Initializing Flags
Bits A30200 through A30215 turn ON while the corresponding CS/CJ CPU Bus Units (Units #0 through #15,
respectively) are initializing.
CS/CJ CPU Bus Unit Setting Error Flag and Unit Number
Bit A40203 is turned ON when the CS/CJ CPU Bus Units actually installed differ from the Units registered in
the I/O table. The unit number of the CS/CJ CPU Bus Unit involved is written to word A427.
Bits A42700 through A42715 correspond to CS/CJ CPU Bus Units #0 through #15, respectively. When a error
occurs, the bit corresponding to the unit number of the CS/CJ CPU Bus Unit involved is turned ON.
CS/CJ CPU Bus Unit Error Flag
Bit A40207 is turned ON when a parity error occurs during the transmission of data between the CPU Unit and
CS/CJ CPU Bus Units. The unit number of the CS/CJ CPU Bus Unit involved is written to word A417.
CS/CJ CPU Bus Unit Numbers
Bits A41000 through A41015 correspond to CS/CJ CPU Bus Units #0 through #15, respectively. When two
CPU Bus Units have the same unit number, the bits corresponding to the unit numbers of the CS/CJ CPU Bus
Units involved are turned ON.
A202
A203 to A210
A219
A302
A401
A402
A410
A417
A427
A501
Word(s)
00 to 07
00 to 15
00 to 07
00 to 15
13
03
07
00 to 15
00 to 15
00 to 15
00 to 15
Bit(s)
cations Enabled) Flags
Port #0 to #7 Execute Error (Network Communica-
tions Execute Error) Flags
CS/CJ CPU Bus Unit Initializing Flags
Duplicate Number Error Flag (fatal error)
CS/CJ CPU Bus Unit Setting Error Flag
CS/CJ CPU Bus Unit Error Flag
CPU Bus Unit Duplicate Number
CS/CJ CPU Bus Unit Error, Unit Number Flags
CS/CJ CPU Bus Unit Setting Error Unit Number
CS/CJ CPU Bus Unit Restart Bits
Communications Port Enabled (Network Communi-
Port #0 to #7 Completion Codes
Memory Areas
Appendix B
Function
345