CV500BI111 Omron, CV500BI111 Datasheet - Page 226

no-image

CV500BI111

Manufacturer Part Number
CV500BI111
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500BI111

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Using the Message Service
CVM1 and CV-series PLCs
I0000
00
1200
01H
1200
00H
1200
00
1200
00
I0000
01
1200
03H
1200
02H
1200
02H
1200
02H
1200
02H
A502
07
A502
07
A502
15
A502
07
A502
07
A502
15
1200
03H
1200
02H
1200
00H
A502
15
Note When using the sample program, make sure that the bits and words used in
the sample program are not the same as those in the user program or Special
I/O Units.
↑XFER
↑SEND D00010
↑RECV
↑XFER
(040)
(192)
(193)
(040)
#0010
A100
#0016
↑MOV
↑MOV
↑MOV
↑MOV
↑MOV
↑MOV
(030)
↑MOV
↑MOV
↑MOV
↑MOV
(030)
(030)
(030)
(030)
(030)
(030)
(030)
(030)
(030)
#000A
#0002
#0400
#0705
#0064
#0010
#0003
#2000
#0705
#0000
(011)
KEEP 120000H
I0000
D00020 D00000
(013)
DIFU
(011)
KEEP 120002H
2000
(013)
DIFU 120003H
2000
120001H
D00000
D00001
D00002
D00003
D00004
D00005
D00006
D00007
D00008
D00009
D00010
D00005
D00040
1210
00H
1210
01H
Creates reset input.
The transmission program will run when I000000 is ON,
provided that the Network Instruction Enabled Flag for
port 7 is ON and the RECV instruction has not been
executed.
CIO 120000H remains ON while the SEND instruction
is being executed, and it turns OFF when the execution
of the instruction has been completed.
The 10-word data starting from I0000 is stored in
D00010 and following words.
Transmission error display
The reception program will run when I000001 is ON,
provided that the Network Instruction Enabled Flag for
port 7 is ON and the SEND instruction has not been
executed.
CIO 120002H remains ON while the RECV instruction
is being executed, and it turns OFF when the execution
of the instruction has been completed.
Transfers 10 words of data from the source node (D00010)
to the PLC (from D00020 onwards) at network address 2,
node no. 4, unit address 0.
Reception error display
Reception data processing
When the data is received without an error, the 16-word
data received at CIO 2000 and following words is
stored in D00040 and following words on the same PLC.
Transfers 16 words of data (from A100 onwards) from
the PLC at network address 3, node no. 32, unit address
0, to words 2000 onwards.
Creates reset input.
Word
D00001 00
D00000 00
D00002 04
D00003 07
D00004 00
Word
D00007 20
D00005 00
D00006 00
D00008 07
D00009 00
Content
Content
02
0A
00
05
64
00
10
03
05
00
Destination node address: 32
Destination Unit address: 0
Destination network address: 2
Number of receive words: 16H
Destination network address: 3
Response required
Communications port no.: 7
Number of retries: 5
Response monitor time: Default
No. of send words: 10H
Destination node address: 4
Destination unit address: 0
Response required
Communications port no.: 7
Number of retries: 5
Response monitor time: 10 s
Meaning
Meaning
Section 6-3
201