G4A-1A-E Omron Corporation, G4A-1A-E Datasheet
G4A-1A-E
Available stocks
Related parts for G4A-1A-E
G4A-1A-E Summary of contents
Page 1
... Standard model available with flux protection construction. Ordering Information Classification #250 tab terminals/PCB coil terminals PCB terminals/PCB coil terminals Note: When ordering, add the rated coil voltage to the model number. Example: G4A-1A-E 12 VDC Model Number Legend G4A- - VDC ...
Page 2
... PCB Power Relay – G4A ■ Contact Ratings Rated load 250 VAC Rated carry current 20 A Max. switching voltage 250 VAC Max. switching current 20 A Max. switching power 5,000 VA Failure rate (ref. value) 100 VDC Note: P level: λ 0 /operation (with an operating frequency of 120 operations/min) ...
Page 3
... PCB Power Relay – G4A DIN EN 61810-1/EN 60255-23 (VDE Reg. No. 6673) Model G4A-1A Engineering Data Maximum Switching Power AC inductive load cosφ = 0.4 Switching voltage (V) 152 Coil ratings VDC Endurance 5,000 3,000 AC resistive load 1,000 700 500 300 100 70 50 Contact ratings ...
Page 4
... PCB Power Relay – G4A Dimensions Note: All units are in millimeters unless otherwise indicated; dimensions shown in parentheses are in inches. G4A-1A-E G4A-1A-PE Precautions Mounting When mounting two or more relays side by side, provide a minimum space between relays. Terminal Connection The terminals fit FASTON receptacle 250 and are suitable for positive-lock mounting. ...