S1D1 Epson Electronics America, Inc., S1D1 Datasheet - Page 532

no-image

S1D1

Manufacturer Part Number
S1D1
Description
LCD Controller-driver With Built-in Character ROM
Manufacturer
Epson Electronics America, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S1D12708F00A1
Manufacturer:
FREESCALE
Quantity:
11
Part Number:
S1D12A04F00A100
Manufacturer:
EPSON
Quantity:
50 000
Part Number:
S1D13005F00A
Manufacturer:
NEC
Quantity:
5
Part Number:
S1D13305F00A
Manufacturer:
EPSON
Quantity:
8 831
Part Number:
S1D13305F00A1
Manufacturer:
EPSON
Quantity:
2 140
Part Number:
S1D13305F00A1
Manufacturer:
EPSON
Quantity:
1 000
Part Number:
S1D13305F00A1
Manufacturer:
EPSON/爱普生
Quantity:
20 000
Company:
Part Number:
S1D13305F00A200
Quantity:
479
Part Number:
S1D13305F00B
Manufacturer:
EPSON
Quantity:
2 100
Part Number:
S1D13305F00B1
Manufacturer:
EPSON/爱普生
Quantity:
20 000
Part Number:
S1D13305F00B100
Manufacturer:
EPSON
Quantity:
1 000
Part Number:
S1D13305F00B100
Manufacturer:
EPSON/爱普生
Quantity:
20 000
Part Number:
S1D13305F00B200
Manufacturer:
EPSON/爱普生
Quantity:
20 000
Part Number:
S1D13305FOA
Manufacturer:
EPSON
Quantity:
3 957
S1D15A06 Series
(10) Display data write
This command writes 8-bit data to the specified DDRAM address. Since the column address is automatically
incremented by +1 after each write ,the MPU can continuously write multiple-word data. See the function explanation
in “DDRAM and page/column address circuit”, for detail.
(11) Read modify write
This command is used paired with End command. Once this command is issued, the column address is not incremented
by Display data read command, but is incremented by Display data write command. This mode is maintained until End
command is issued. When End command is issued, the column address returns to the address it was at when Read modify
write command was issued. This function makes it possible to reduce the MPU load when there are the data to change
repeatedly in a specified display region, such as blinking cursor.
*When End command is issued, only column address returns to the address it was at when Read modify write command
*Even if Read modify write mode, other commands besides Display data read/write can also be used. However, Column
12–28
was issued, but page address does not return. Consequently, Read modify Write mode cannot be used over pages.
When you want to maintain the current page address after a read modify write operation done on a column address
between the start and the final column address (65H), you must specify the page address again after the operation is
over.
address set command cannot be used.
A0
A0
1
0
RD WR
RD WR
E
E
1
1
R/W
R/W
0
0
D7
D7
1
D6
D6
1
D5
D5
1
The sequence for cursor display
Write Data
D4
D4
0
No
Column address set
Read modify Write
Page address set
D3
D3
0
Figure 13
EPSON
Dummy read
Completed?
Data read
Data write
End
D2
D2
0
Yes
D1
D1
0
D0
D0
0
Rev. 1.0a