S1D1 Epson Electronics America, Inc., S1D1 Datasheet - Page 309

no-image

S1D1

Manufacturer Part Number
S1D1
Description
LCD Controller-driver With Built-in Character ROM
Manufacturer
Epson Electronics America, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S1D12708F00A1
Manufacturer:
FREESCALE
Quantity:
11
Part Number:
S1D12A04F00A100
Manufacturer:
EPSON
Quantity:
50 000
Part Number:
S1D13005F00A
Manufacturer:
NEC
Quantity:
5
Part Number:
S1D13305F00A
Manufacturer:
EPSON
Quantity:
8 831
Part Number:
S1D13305F00A1
Manufacturer:
EPSON
Quantity:
2 140
Part Number:
S1D13305F00A1
Manufacturer:
EPSON
Quantity:
1 000
Part Number:
S1D13305F00A1
Manufacturer:
EPSON/爱普生
Quantity:
20 000
Company:
Part Number:
S1D13305F00A200
Quantity:
479
Part Number:
S1D13305F00B
Manufacturer:
EPSON
Quantity:
2 100
Part Number:
S1D13305F00B1
Manufacturer:
EPSON/爱普生
Quantity:
20 000
Part Number:
S1D13305F00B100
Manufacturer:
EPSON
Quantity:
1 000
Part Number:
S1D13305F00B100
Manufacturer:
EPSON/爱普生
Quantity:
20 000
Part Number:
S1D13305F00B200
Manufacturer:
EPSON/爱普生
Quantity:
20 000
Part Number:
S1D13305FOA
Manufacturer:
EPSON
Quantity:
3 957
S1D15605 Series
• Electronic Volume Register Set
By using this command to set six bits of data to the electronic volume register, the liquid crystal drive voltage V
one of the 64 voltage levels.
When this command is input, the electronic volume mode is released after the electronic volume register has been set.
When the electronic volume function is not used, set this to (1, 0, 0, 0, 0, 0)
• The Electronic Volume Register Set Sequence
(19) Static Indicator (Double Byte Command)
This command controls the static drive system indicator display. The static indicator display is controlled by this
command only, and is independent of other display control commands.
This is used when one of the static indicator liquid crystal drive electrodes is connected to the FR terminal, and the other
is connected to the FRS terminal. A different pattern is recommended for the static indicator electrodes than for the
dynamic drive electrodes. If the pattern is too close, it can result in deterioration of the liquid crystal and of the
electrodes.
The static indicator ON command is a double byte command paired with the static indicator register set command, and
thus one must execute one after the other. (The static indicator OFF command is a single byte command.)
• Static Indicator ON/OFF
When the static indicator ON command is entered, the static indicator register set command is enabled. Once the static
indicator ON command has been entered, no other command aside from the static indicator register set command can
be used. This mode is cleared when data is set in the register by the static indicator register set command.
8–54
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
0
0
0
0
0
0
E R/W
E R/W
1
1
1
1
1
1
0
0
0
0
0
0
1
*
*
*
*
*
0
*
*
*
*
*
0
0
0
1
1
1
0
0
0
1
1
0
No
0
0
0
1
1
1
Electronic volume register set
Electronic volume mode set
0
0
0
1
1
1
Changes complete?
0
1
1
1
1
0
1
0
1
0
1
0
1
Yes
Figure 26
EPSON
Electronic volume mode clear
Static Indicator
Small
Large
| V
OFF
ON
5
* Inactive bit
|
Rev. 2.4a
5