AT32UC3C0512CAU Atmel Corporation, AT32UC3C0512CAU Datasheet - Page 211

no-image

AT32UC3C0512CAU

Manufacturer Part Number
AT32UC3C0512CAU
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3C0512CAU

Flash (kbytes)
512 Kbytes
Pin Count
144
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
123
Ext Interrupts
144
Usb Transceiver
1
Quadrature Decoder Channels
2
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
7
Twi (i2c)
3
Uart
5
Can
2
Lin
5
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
2000
Analog Comparators
4
Resistive Touch Screen
No
Dac Channels
4
Dac Resolution (bits)
12
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
68
Self Program Memory
YES
External Bus Interface
1
Dram Memory
sdram
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0 to 3.6 or 4.5 to 5.5
Operating Voltage (vcc)
3.0 to 3.6 or 4.5 to 5.5
Fpu
Yes
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
22
Input Capture Channels
12
Pwm Channels
20
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3C0512CAU-ALUT
Manufacturer:
Atmel
Quantity:
10 000
13.5.1.1
13.5.2
13.5.3
32117C–AVR-08/11
Measurement
Interrupts
Cautionary note
Note that if clock selected as source for CLK_REF is stopped during a measurement, this will
not be detected by the FREQM. The BUSY bit in the STATUS register will never be cleared, and
the DONE interrupt will never be triggered. If the clock selected as soruce for CLK_REF is
stopped, it will not be possible to change the source for the reference clock as long as the
selected source is not running.
In the Mode Register the Clock Source Selection (CLKSEL) field selects CLK_MSR and the
Number of Reference Clock Cycles (REFNUM) field selects the duration of the measurement.
The duration is given in number of CLK_REF periodes.
Writing a one to the START bit in the Control Register (CTRL) starts the measurement. The
BUSY bit in SR is cleared when the measurement is done.
The result of the measurement can be read from the Value Register (VALUE). The frequency of
the measured clock CLK_MSR is then:
The FREQM has two interrupt sources:
These will generate an interrupt request if the corresponding bit in the Interrupt Mask Register
(IMR) is set. The interrupt sources are ORed together to form one interrupt request. The FREQM
will generate an interrupt request if at least one of the bits in the Interrupt Mask Register (IMR) is
set. Bits in IMR are set by writing a one to the corresponding bit in the Interrupt Enable Register
(IER) and cleared by writing a one to this bit in the Interrupt Disable Register (IDR). The interrupt
request remains active until the corresponding bit in the Interrupt Status Register (ISR) is
cleared by writing a one to this bit in the Interrupt Clear Register (ICR). Because all the interrupt
sources are ORed together, the interrupt request from the FREQM will remain active until all the
bits in ISR are cleared.
• Write a zero to the MODE.REFCEN to disable he clock, without changing the other bits/fields
• Wait until the SR.RCLKBUSY bit reads as zero.
• DONE: A frequency measurement is done
• RCLKRDY: The reference clock is ready
in the Mode register.
f
CLK_MSR
= (VALUE/REFNUM)*f
CLK_REF
AT32UC3C
211