AT32UC3C0512CAU Atmel Corporation, AT32UC3C0512CAU Datasheet - Page 1235

no-image

AT32UC3C0512CAU

Manufacturer Part Number
AT32UC3C0512CAU
Description
Manufacturer
Atmel Corporation

Specifications of AT32UC3C0512CAU

Flash (kbytes)
512 Kbytes
Pin Count
144
Max. Operating Frequency
66 MHz
Cpu
32-bit AVR
# Of Touch Channels
32
Hardware Qtouch Acquisition
No
Max I/o Pins
123
Ext Interrupts
144
Usb Transceiver
1
Quadrature Decoder Channels
2
Usb Speed
Full Speed
Usb Interface
Device + OTG
Spi
7
Twi (i2c)
3
Uart
5
Can
2
Lin
5
Ssc
1
Ethernet
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
16
Adc Resolution (bits)
12
Adc Speed (ksps)
2000
Analog Comparators
4
Resistive Touch Screen
No
Dac Channels
4
Dac Resolution (bits)
12
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
68
Self Program Memory
YES
External Bus Interface
1
Dram Memory
sdram
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
3.0 to 3.6 or 4.5 to 5.5
Operating Voltage (vcc)
3.0 to 3.6 or 4.5 to 5.5
Fpu
Yes
Mpu / Mmu
Yes / No
Timers
6
Output Compare Channels
22
Input Capture Channels
12
Pwm Channels
20
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3C0512CAU-ALUT
Manufacturer:
Atmel
Quantity:
10 000
39.6.6.9
39.6.7
Table 39-30. aWire Command Summary
32117C–AVR-08/11
COMMAND
0x01
0x02
0x03
0x04
0x05
0x06
aWire Command Summary
CRC Errors/NACK Response
JTAG_ID
MEMORY_SPEED_REQUEST
Instruction
AYA
STATUS_REQUEST
TUNE
CHIP_ERASE
Two instructions exist to access the SAB: MEMORY_WRITE and MEMORY_READ. These two
instructions write and read words, halfwords, and bytes from the SAB.
Busy Reporting
If the aWire master, during a MEMORY_WRITE or a MEMORY_READ command, transmit
another byte when the aWire is still busy sending the previous byte to the SAB, the AW will
respond with a MEMORY_READ_WRITE_STATUS error. See chapter
more details.
The aWire master should adjust its baudrate or delay between bytes when doing SAB accesses
to ensure that the SAB is not overwhelmed with data.
Error Reporting
If a write is performed on a non-existing memory location the SAB interface will respond with an
error. If this happens, all further writes in this command will not be performed and the error and
number of bytes written is reported in the MEMORY_READWRITE_STATUS message from the
AW after the write.
If a read is performed on a non-existing memory location, the SAB interface will respond with an
error. If this happens, the data bytes read after this event are not valid. The AW will include three
extra bytes at the end of the transfer to indicate if the transfer was successful, or in the case of
an error, how many valid bytes were received.
The AW will calculate a CRC value when receiving the command, length, and data fields of the
command packets. If this value differs from the value from the CRC field of the packet, the AW
will reply with a NACK response. Otherwise the command is carried out normally.
An unknown command will be replied with a NACK response.
In worst case a transmission error can happen in the length or command field of the packet. This
can lead to the aWire slave trying to receive a command with or without length (opposite of what
the master intended) or receive an incorrect number of bytes. The aWire slave will then either
wait for more data when the master has finished or already have transmitted the NACK
response in congestion with the master. The master can implement a timeout on every com-
mand and reset the slave if no response is returned after the timeout period has ended.
The implemented aWire commands are shown in the table below. The responses from the AW
are listed in
Section
39.6.8.
Description
“Are you alive”.
Asks AW to return the JTAG IDCODE.
Request a status message from the AW.
Tell the AW to report the current baud rate.
Reports the speed difference between the aWire control and the SAB clock
domains.
Erases the flash and all volatile memories.
AT32UC3C
Section 39.6.8.5
1235
for

Related parts for AT32UC3C0512CAU