PI7C7300ANAE Pericom Semiconductor, PI7C7300ANAE Datasheet - Page 53

no-image

PI7C7300ANAE

Manufacturer Part Number
PI7C7300ANAE
Description
IC PCI-PCI BRIDGE 3PORT 272-BGA
Manufacturer
Pericom Semiconductor
Datasheet

Specifications of PI7C7300ANAE

Applications
*
Interface
*
Voltage - Supply
*
Package / Case
272-PBGA
Mounting Type
Surface Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PI7C7300ANAE
Manufacturer:
Pericom
Quantity:
10 000
to the initiator. When PI7C7300A detects a parity error on the write data for the initial
delayed write request transaction, the following events occur:
!
!
Note: If parity checking is turned off and data parity errors have occurred for queued or
subsequent delayed write transactions on the initiator bus, it is possible that the initiator’s
re-attempts of the write transaction may not match the original queued delayed write
information contained in the delayed transaction queue. In this case, a master timeout
condition may occur, possibly resulting in a system error (P_SERR# assertion).
For downstream transactions, when PI7C7300A is delivering data to the target on the
secondary bus and S_PERR# is asserted by the target, the following events occur:
!
!
Similarly, for upstream transactions, when PI7C7300A is delivering data to the target on
the primary bus and P_PERR# is asserted by the target, the following events occur:
!
!
A delayed write transaction is completed on the initiator bus when the initiator repeats
the write transaction with the same address, command, data, and byte enable bits as the
delayed write command that is at the head of the posted data queue. Note that the parity
bit is not compared when determining whether the transaction matches those in the
delayed transaction queues.
Two cases must be considered:
!
!
If the parity-error-response bit corresponding to the initiator bus is set, PI7C7300A
asserts TRDY# to the initiator and the transaction is not queued. If multiple data
phases are requested, STOP# is also asserted to cause a target disconnect. Two
cycles after the data transfer, PI7C7300A also asserts PERR#.
If the parity-error-response bit is not set, PI7C7300A returns a target retry. It queues
the transaction as usual. PI7C7300A does not assert PERR#. In this case, the
initiator repeats the transaction.
PI7C7300A sets the detected-parity-error bit in the status register corresponding to
the initiator bus, regardless of the state of the parity-error-response bit.
PI7C7300A sets the secondary interface data parity detected bit in the secondary
status register, if the secondary parity error response bit is set in the bridge control
register.
PI7C7300A captures the parity error condition to forward it back to the initiator on
the primary bus.
PI7C7300A sets the primary interface data-parity-detected bit in the status register, if
the primary parity-error-response bit is set in the command register.
PI7C7300A captures the parity error condition to forward it back to the initiator on
the secondary bus.
When parity error is detected on the initiator bus on a subsequent re-attempt of the
transaction and was not detected on the target bus
When parity error is forwarded back from the target bus
Page 53 OF 109
3-PORT PCI-TO-PCI BRIDGE
ADVANCE INFORMATION
09/25/03 Revision 1.09
PI7C7300A

Related parts for PI7C7300ANAE