PI7C7300ANAE Pericom Semiconductor, PI7C7300ANAE Datasheet - Page 30

no-image

PI7C7300ANAE

Manufacturer Part Number
PI7C7300ANAE
Description
IC PCI-PCI BRIDGE 3PORT 272-BGA
Manufacturer
Pericom Semiconductor
Datasheet

Specifications of PI7C7300ANAE

Applications
*
Interface
*
Voltage - Supply
*
Package / Case
272-PBGA
Mounting Type
Surface Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PI7C7300ANAE
Manufacturer:
Pericom
Quantity:
10 000
4.7.7
4.8
4.8.1
PI7C7300A has the capability to post multiple delayed read requests, up to a maximum
of four in each direction. If an initiator starts a read transaction that matches the address
and read command of a read transaction that is already queued, the current read
command is not posted as it is already contained in the delayed transaction queue.
See Section 6 for a discussion of how delayed read transactions are ordered when
crossing PI7C7300A.
FAST BACK-TO-BACK READ TRANSACTION
PI7C7300A can recognize fast back-to-back read transactions.
CONFIGURATION TRANSACTIONS
Configuration transactions are used to initialize a PCI system. Every PCI device
has a configuration space that is accessed by configuration commands. All registers are
accessible in configuration space only.
In addition to accepting configuration transactions for initialization of its own
configuration space, the PI7C7300A also forwards configuration transactions for device
initialization in hierarchical PCI systems, as well as for special cycle generation.
To support hierarchical PCI bus systems, two types of configuration transactions are
specified: Type 0 and Type 1.
Type 0 configuration transactions are issued when the intended target resides on the same
PCI bus as the initiator. A Type 0 configuration transaction is identified by the
configuration command and the lowest two bits of the address set to 00b.
Type 1 configuration transactions are issued when the intended target resides on another
PCI bus, or when a special cycle is to be generated on another PCI bus. A Type 1
configuration command is identified by the configuration command and the lowest two
address bits set to 01b.
The register number is found in both Type 0 and Type 1 formats and gives the DWORD
address of the configuration register to be accessed. The function number is also included
in both Type 0 and Type 1 formats and indicates which function of a multifunction
device is to be accessed. For single-function devices, this value is not decoded. The
addresses of Type 1 configuration transaction include a 5-bit field designating the device
number that identifies the device on the target PCI bus that is to be accessed. In addition,
the bus number in Type 1 transactions specifies the PCI bus to which the transaction is
targeted.
TYPE 0 ACCESS TO PI7C7300A
The configuration space is accessed by a Type 0 configuration transaction on the primary
interface. The configuration space cannot be accessed from the secondary bus. The
PI7C7300A responds to a Type 0 configuration transaction by asserting P_DEVSEL#
when the following conditions are met during the address phase:
Page 30 OF 109
3-PORT PCI-TO-PCI BRIDGE
ADVANCE INFORMATION
09/25/03 Revision 1.09
PI7C7300A

Related parts for PI7C7300ANAE