F39-EU1E Omron, F39-EU1E Datasheet - Page 9

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
“Safe” “Simple” “Visible” Safety
controller with no need for
programming
■ Conforms to global safety standards.
■ All-in-one constructions for easy multi-input safety circuits.
■ Information where you need it: LED indicators, auxiliary
Features
OMRON believes the fundamentals for building risk-free workplace environments are safety, simplicity, and visibility.
Design and implementation of safety measures and policies can be readily achieved through proven safety procedures using simple connections.
Peace of mind is attained by communicating safety equipment status information* in a form that is meaningful to the on-site operational and
maintenance staff supporting the system.
The F3SX evolves from this philosophy.
* Information:
1. Indicator output with self-diagnostic functions clearly communicates proximity warnings and work permission during operation to the operator.
2. The lighting patterns of the Safety Controller's indicators allow the operator to read the ON/OFF status of safety equipment I/O as well as error
3. RS-232 communications can be used to read detailed information for the above status.
What is a Safety Controller?
Are Your Safety Inputs Connected to Your PLC Built with Interlocks?
Generally, safety is jeopardized in PLCs and other programmable control devices due to partial memory loss, CPU runaways, and situations such
as on-site overwriting of programs. Using Safety Light Curtains and Safety-door Switches on their own does not necessarily ensure sufficient safety
for PLC operation. Nor is safety fully secured through the use of relays in interlocks due to hazardous events that occur as a result of fused relays
or short-circuited wiring.
The F3SX offers safe and simple connections for an array of safety equipment, such as Safety Light Curtains and Safety-door Switches, functioning
as a central hub to perform integrated monitoring of various safety equipment.
● Interlock with Safety Input Connected to a PLC
Safety Controllers
F3SX
outputs, and serial communications.
type information.
Be sure to read the “Safety Precautions” on page 21
A22E
Emergency Stop
Switch
D4GS-N
Safety-door
Switch
F3SN-A/B
Safety Light Curtain
http://www.ia.omron.com/
CJ1-series
Programmable Controller
M
KM3
● Interlock Using an F3SX as the Safety Input
.
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
A22E
Emergency Stop
Switch
D4GS-N
Safety-door Switch
F3SN-A/B
Safety Light Curtain
Safety Controller
F3SX
M
KM3
KM1
KM2
1