F39-EU1E Omron, F39-EU1E Datasheet - Page 159

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
G9SX-BC202 (24 VDC) (2-channel Emergency Stop Switch Input / Manual Reset) +
G9SX-AD322-T15 (24 VDC) (2-channel Safety Limit Switch Input / Auto Reset)
+24 V
Note: This example corresponds to category 4.
GND
open
S1
+24 V
G9SX-BC202 (Unit 1)
G9SX-AD322-T15 (Unit 2)
A1
A1
A2
A2
GND
S4
T11
T11
(Operation command)
KM1 KM2
KM3 KM4
S14
S14
Control circuit
23
24
Motor controller
T12 T21 T22 T31 T32 T33 Y1
T12 T21 T22 T31 T32 T33 Y1
http://www.ia.omron.com/
S24
S24 S34 S44 S54 L1 X1 X2
11
12
S3
Control circuit
11
12
KM5 KM6
21
22
L1 L2
S2
+24
Feedback Loop
Feedback Loop
KM1
KM2
V
+24 V
X1 X2
PLC etc.
PLC etc.
KM3
KM4
KM5
KM6
NC
NC
T41 T42
AND
OFF
KM3
KM 4
KM 1
KM2
S1:
S2:
S3:
S4:
KM1 to KM6: Contactor
M1 to M3:
M2
M1
Emergency stop switch S1
KM1, KM2 N.O. contact
KM3, KM4 N.O. contact
KM5, KM6 N.O. contact
KM6
KM1, KM2 N.C. contact
KM3, KM4 N.C. contact
KM5, KM6 N.C. contact
KM5
Timing chart
G9SX-BC202 (Unit 1)
Unit 1
Logical AND output L1
G9SX-AD322-T15 (Unit 2)
Unit 2
Logical AND input T41
Safety limit switch S3
Unit 2 S14, S24, S34
Emergency Stop Switch
Reset Switch
Safety Limit Switch
Limit Switch
3-phase motor
Motor controller
Operation command
(1) Door opened: Only the Unit 2 stops.
(2) Emergency stop button pressed: Both the Unit 1 and 2 stop.
Rotation of motor
Reset switch S2
Unit 1 S14, S24
Unit 2 S44, S54
M3
Limit switch S4
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
S34
OFF-delay time
(1)
OFF-delay time
(2)
G9SX