F39-EU1E Omron, F39-EU1E Datasheet - Page 672

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
F3SJ-A@@@@P20-TS/P25-TS
Sensor type
Software version
Setting tool connection
Applicable safety category
Detection capability
Beam gap (P)
Number of beams (n)
Protective height (PH)
Lens diameter
Operating range
Response time
(For details, see
"Response Time"
on page 20.)
Startup waiting time
Power supply voltage (Vs)
Current
consumption
(no load)
Light source
(emitted wavelength)
Effective aperture angle (EAA) Based on IEC61496-2. Within 2.5 for both emitter and receiver when the detection distance is 3 m or over
Control outputs (OSSD)
Auxiliary output 1
(non-safety output)
External indicator output
(non-safety output)
Output operation
mode
Input voltage
Internal indicators
Model
ON to
OFF
OFF to
ON
Emitter
Receiver
Receiver
Emitter
Emitter
Receiver
http://www.ia.omron.com/
Type 4 safety light curtain
Ver. 2
Parameter setting: Not possible
Monitoring: Possible
Category 4, 3, 2, 1, or B
Opaque objects
20 mm in diameter
15 mm
16 to 166
245 to 2,495 mm
Diameter 5 mm
0.2 to 9 m (protective height 1,640 mm max.), 0.2 to 7 m (protective height 1,655 mm max.)
1 set, 0245 to 1,205: 10 ms to 15 ms max.
1,220 or higher: 17.5 ms to 22.5 ms max.
3 sets (240 beams): 45.5 ms
1 set, 0245 to 1,205: 40 ms to 60 ms max.
1,220 or higher: 70 ms to 90 ms max.
3 sets (240 beams): 200 ms
2 s max. (2.2 s max. for series connection)
24 VDC 20% (ripple p-p10% max.)
Up to 50 beams: 76 mA max., 51 to 100 beams: 106 mA max., 101 to 150 beams: 130 mA max.,
151 to 166 beams: 153 mA max
Up to 50 beams: 68 mA max., 51 to 100 beams: 90 mA max., 101 to 150 beams: 111 mA max.,
151 to 166 beams: 128 mA max.
Infrared LED (870 nm)
Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),
allowable capacity load 2.2 F, leak current 1 mA max.
One PNP transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),
Available indicators
Control outputs 1, 2:
Auxiliary output 1:
External indicator output 1: Inverse of control output signals for a basic system (Operating mode can be changed with the setting
External indicator output 2: ON when lock-out for a basic system (Operating mode can be changed with the setting tool.)
Test input, reset input, and muting input are all
ON voltage:9 to 24 V (Vs) (sink current: 3 mA max.)
OFF voltage:0 to 1.5 V, or open
External device monitoring input
ON voltage:9 to 24 V (Vs) (sink current: 5 mA max.)
OFF voltage:0 to 1.5 V, or open
Light intensity level indicators (green LED
Error mode indicators (red LED
Power indicator (green LED
Lockout indicator (yellow LED
Light intensity level indicators (green LED
Error mode indicators (red LED
OFF output indicator (red LED
ON output indicator (green LED
according to function
(This can be different from traditional logic (ON/OFF) because safety circuit is used.)
leak current 1 mA max.
External device monitoring indicator (muting input 1 indicator), Test indicator (muting input 2 indicator) (green LED
ON/flash according to function
Incandescent lamp: 24 VDC, 3 to 7 W
LED lamp: Load current 10 mA to 300 mA max., leak current 1 mA max.
(To use an external indicator, an F39-JJ3N universal indicator cable or an F39-A01P@-PAC dedicated external indicator kit is
required.)
F3SJ-A@@@@P20-TS
ON when receiving light
Inverse of control output signals (Operating mode can be changed with the setting tool.)
tool.)
ON when muting/override for a muting system (Operating mode can be changed with the setting tool.)
ON when muting/override for a muting system (Operating mode can be changed with the setting tool.)
1): ON while power is on
1): Blinks to indicate lockout.
1): ON when safety output is OFF, blinks at lockout.
3): Blink to indicate error details
3): Blink to indicate error details
1): ON while safety output is ON muting error indicator, Test indicator (green LED 2): ON/flash
2, orange LED
2, orange LED
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
3): ON based on the light intensity
3): ON based on the light intensity
Opaque objects
25 mm in diameter
20 mm
13 to 125
260 to 2,500 mm
1 set, 0260 to 1,600: 10 ms to 15 ms max.
1,620 or higher: 17.5 ms to 20.0 ms max.
3 sets (240 beams): 45.5 ms
1 set, 0260 to 1,600: 40 ms to 60 ms max.
1,620 or higher: 70 ms to 80 ms max.
3 sets (240 beams): 200 ms
F3SJ-A@@@@P25-TS
F3SJ Ver.2
2):
18

Related parts for F39-EU1E