F39-EU1E Omron, F39-EU1E Datasheet - Page 600

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
18. Connect to the G9SX-NS@ only appropriate components or
19. OMRON is not responsible for conformity with any safety
20. Be careful not to have your fingers caught when mounting terminal
21. The service life will depend on the switching conditions. Be sure
devices complying with relevant safety standards corresponding
to the required level of safety category.
Conformity to requirements of safety category must be
determined as an entire system. It is recommended to consult an
authorized certification body regarding assessment of conformity
to the required safety level.
standards covering the customer's entire system.
blocks.
to check the actual operating conditions using the actual devices,
and make sure that the number of switching operations will not
cause performance problems.
http://www.ia.omron.com/
1. Connection with Non-contact Door Switch
2. The D40A must be used with a designated actuator and
3. Handle with Care.
4. Storage and Operating Conditions
5. Use cables with a length of less than 100 m total to connect D40A
6. Disconnect the G9SX-NS@ from the power supply when replacing
7. Do not use the D40A in a magnetic field of 1.5 mT or higher. The
8. Do not use the D40A in the water or in an environment
9. Be sure to mount a guard stopper and guide to prevent the D40A
10. Do not use the switch or actuator as a stopper. Protect the switch
G9SX-NS202-@
G9SX-NSA222-T03-@
Wire conductors between the G9SX-NS@ and the D40A
Non-contact Door Switch correctly and verify operation, before
using the system.
G9SX-NS@ Controller.
Do not drop the product or expose it to excessive vibration or
mechanical shock. The product may be damaged and may not
function properly.
Do not store or use the products under the following conditions.
1. In direct sunlight
2. At ambient temperatures not between 10 and 55°C
3. At relative humidity not between 25% and 85% or under
4. In corrosive or combustible gases
5 Where subject to vibration or mechanical shock beyond the
6. Where subject to contact with water, oil, or chemicals
7. In an atmosphere containing excessive dust, saline, or metal
8. Where iron filings or powder may fall on the product
Switches.
the D40A. Devices connected to the G9SX-NS@ may operate
unexpectedly.
D40A may not function properly.
continuously exposed to water. Water may penetrate into the
D40A. (The IP67 degree of protection for this switch means that it
has been checked for penetration of water after having been left
in water for a fixed period of time.)
Non-contact Door Switch from being subjected to impact.
and the actuator by installing a stopper. Separate the switch and
the actuator to a distance of 1 mm or more.
D1 D2 D3 D4
temperature changes that could causes condensation
rated values
powder
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Total wiring length 100 m max.
Precautions for Correct Use
D40A/G9SX-NS
25

Related parts for F39-EU1E