F39-EU1E Omron, F39-EU1E Datasheet - Page 261

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Structure and Nomenclature
Structure
A4EG-C000041
Contact Forms
Operating Patterns
A4EG-C000041
A4EG-BE2R041
A4EG-BM2B041
* Refer to Dimensions on page 6 for information on the positions of
Note: 1. The contact ON/OFF timing is not synchronized. Confirm
Enabling Switch
Emergency
stop switch
output
Pushbutton
switch output
pushbutton switches A and B.
Enable output
Enable output
Enable output
Pushbutton
Pushbutton
Grip output
Terminal 5
Terminal 6
Operation
Operation
Operation
Terminal 2
Terminal 1
switch
switch
OPEN
CLOSED
2. Direct opening only during grip.
Section
performance before application.
Terminal No.
Terminal No.
Terminal No.
Terminal No.
(pushbutton switch A) *
(pushbutton switch B) *
1 to 2
3 to 4
5 to 6
1 to 2
3 to 4
5 to 6
7 to 8
1 to 2
3 to 4
ON: CLOSED
OFF: OPEN
http://www.ia.omron.com/
Terminal No.
5 to 6
7 to 8
Terminal 3
Terminal 4
Position 1
Position 1
Position 1
Reset (turn reset)
Operation (push)
A4EG-BE2R041
A4EG-BM2B041
Terminal 5
Terminal 6
Terminal 2
Terminal 1
Operation
Operation
Position 2
Position 2
Position 2
Push
Push
OFF → ON
OFF → ON
ON → OFF
OFF → ON
Emergency Stop
Switch Section/
Pushbutton Switch
Section
Terminal 8
Terminal 7
Terminal 3
Terminal 4
Contact
Contact
Position 3
Position 3
Position 3
Operating Characteristics
Chart (Enabling Switch Section)
Operating Stroke (Enabling Switch Section)
Operating Force (Enabling Switch Section:
Reference Values)
* HF: Holding force
Operating Force (Emergency Stop Switch
Section: Reference Values)
Operating Force (Pushbutton Switch Section:
Reference Value)
Operating characteristics
Enable output (ON)
Max. enable holding position
Enable direct opening position
Max. stroke
Operating characteristics
Enable operating force
Enable holding force
Grip operating force
Operating characteristics
Operating force
Reset force
Operating characteristics
Operating force
Three Positions: OFF - ON - OFF
Contact Configuration
* Terminal No. (5), (6): A4EG-C000041 only
Terminal No.
Terminal No.
Not Gripped
Position 1
Enabling Switch
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
Enable output
(1-2, 3-4)
Grip output
(5-6)
OFF
(2)
(1)
OF2
OF1
(4)
(3)
HF
Gripped lightly
(6)
(5)
PT1
Released
*
*
Terminal No.
Terminal No.
Emergency Stop Switch
PT2
Gripped to
Middle
Position
(5)
(7)
Position 2
Released
TT1
TT2
OF2 max.
OF max.
PT2 max.
PT3 max.
OF1 max.
HF *
RF max.
OF max.
ON
TT1 PT3 PT4 TT2
Operating stroke
Terminal No.
(6)
(8)
Gripped Farther
Specified value
Specified value
Specified value
Specified value
Approx. 4.2 mm
Approx. 6.7 mm
Terminal No.
(5)
(7)
Approx. 8 N
Pushbutton Switch
0.1 N·m
3.6 mm
6.0 mm
Gripped past
Middle
Position
14.7 N
14 N
40 N
4 N
Position 3
A4EG
OFF
Terminal No.
(6)
(8)
5

Related parts for F39-EU1E