F39-EU1E Omron, F39-EU1E Datasheet - Page 670

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Input voltage
Internal indicators
Mutual interference
prevention function
Series connection
Test functions
Safety functions
Model
PNP
output
NPN
output
Emitter
Receiver
outputs
outputs
http://www.ia.omron.com/
PNP
NPN
Test input, interlock selection input, reset input, and muting input are all
ON voltage:9 to 24 V (Vs) (sink current: 3 mA max.)
OFF voltage:0 to 1.5 V, or open
External device monitoring input
ON voltage:9 to 24 V (Vs) (sink current: 5 mA max.)
OFF voltage:0 to 1.5 V, or open
Test input, interlock selection input, reset input, and muting input are all
ON voltage:0 to 1.5 V (short-circuit current 3 mA max.)
OFF voltage:9 to 24 V, or open
External device monitoring input
ON voltage:0 to 1.5 V (short-circuit current 5 mA max.)
OFF voltage:9 to 24 V, or open
Light intensity level indicators (green LED
Error mode indicators (red LED
Power indicator (green LED
Interlock indicator (yellow LED
External device monitoring indicator (muting input 1 indicator), Blanking/test indicator (muting input 2 indicator) (green LED
ON/flash according to function
Light intensity level indicators (green LED
Error mode indicators (red LED
OFF output indicator (red LED
ON output indicator (green LED
ON/flash according to function
Interference light prevention algorithm, detection distance change function
Time division emission by series connection
Number of connections: up to 4 sets
Total number of beams: up to 400 beams
Maximum cable length for 2 sets: no longer than 15 m
Response time under connection: See page 20
Self test (when power is turned ON and while power is supplied)
External test (emission stop function by test input)
Start interlock, restart interlock (Must be set with a setting tool when the muting function is used.)
External device monitor
Muting (Lamp burnout detection, override function included. F39-CN6 key cap for muting is required.)
Fixed blanking (must be set by a setting tool)
Floating blanking (must be set by a setting tool)
F3SJ-A@@@@N14
F3SJ-A@@@@P14
1): ON while power is on
1): ON when safety output is OFF, blinks at lockout.
1): ON while under interlock, ON while under interlock, blinks at lockout.
3): Blink to indicate error details
3): Blink to indicate error details
1): ON while safety output is ON muting error indicator, Blanking /test indicator (green LED
F3SJ-A@@@@N20
F3SJ-A@@@@P20
2, orange LED
2, orange LED
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
3): ON based on the light intensity
3): ON based on the light intensity
F3SJ-A@@@@P30
F3SJ-A@@@@N30
---
F3SJ-A@@@@P55
F3SJ Ver.2
---
2):
2):
16

Related parts for F39-EU1E