F39-EU1E Omron, F39-EU1E Datasheet - Page 808

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
F3SX-N-L2R (Manual Reset)
For category 4 rating
24 VDC
Timing Chart
Wiring for use of the test
function of the Light Curtain
E1
Reset switch (S2)
Emergency stop
switch (S1)
F3SN-A@SS
control outputs
1 and 2
F3SX-N-L2R
R output
External indicator
KM1, KM2
Motor (M)
S1
M
Test
switch
A2
A1
24V
SSC AS3 AS2 AS1
T11 T12 T21 T22
24 V
E1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Rotate
Stop
Note: This timing chart does not allow for I/O device response delays.
Control circuits
E1
KM1
KM2
24 VDC
http://www.ia.omron.com/
External indicator
24 VDC
EL1 EL2 FB
Y1 Y2
Reset input
0 V
F39-JC@A-L or
F39-JC@E@-L
Cable with
Connector on One
End (for Emitter)
S2
24 V
Y3
E1
15
2
interrupted
F3SN
8
9
light
Emitter
Emitter
11
6
F3SX-N-L2R
incident
16
1
F3SN
light
F3SN-A@SS
F3SN-A@SS
14
3
RS-485(B)
RS-485(A)
RS-485(B)
RS-485(A)
Reset input
(pink)
(gray)
(pink)
(gray)
13
4
12
5
10
7
Receiver
Receiver
Emergency
stop switch
OFF
K1
K2
F39-JC@A-D or
F39-JC@E@-D
Cable with
Connector on One
End (for Receiver)
Fuses
12
11
Emergency
stop switch
KM1 KM2
23 33
24
ON
34
Reset input
S1:
S2:
KM1, KM2: Relay with forcibly guided contacts or magnetic contactor
M:
E1:
External indicator: Filament-type indicator
Note: 1. The above circuit diagram conforms to Category 4.
AC
2. In this connection example, the auxiliary output is set to the
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
To operate using non-standard settings, refer to the catalog or
Use the optional F39-MC11 Setting Console to disable the EDM.
standard setting (Dark-ON operation).
Instruction Manual for the F3SN-A@SS.
Emergency stop switch (A165E, A22E)
Reset switch
Three-phase motor
24-VDC power supply (S82K)
(When an external indicator is not necessary, connect
resistance of 1/4 W, 4.7 kΩ.)
F3SN-A@SS
19

Related parts for F39-EU1E