F39-EU1E Omron, F39-EU1E Datasheet - Page 441

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Specifications
Ratings
Coil
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.
Contacts
Characteristics
Note: The above values are initial values.
*1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method.
*2. These times were measured at the rated voltage and an ambient temperature of 23°C. Contact bounce time is not included.
*3. The response time is the time it takes for the normally open contacts to open after the coil voltage is turned OFF. Contact bounce time is
*4. The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric strength was measured.
*5. Pole 3 refers to terminals 33−34, pole 4 refers to terminals 43−44, pole 5 refers to terminals 53−54, and pole 6 refers to terminals
*6. The durability is for an ambient temperature of 15 to 35°C and an ambient humidity of 25% to 75%.
*7. The failure rate is based on an operating frequency of 300 operations/min.
*8. When operating at a temperature between 70 and 85°C, reduce the rated carry current (6 A at 70°C or less) by 0.1 A for each degree above 70°C.
Rated voltage
Item
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Contact resistance *1
Operating time *2
Response time *3
Release time *2
Maximum operating
frequency
Insulation resistance *4
Dielectric strength *5
Vibration resistance
Shock resistance
Durability *6
Failure rate (P level)
(reference value *7)
Ambient operating temperature *8 −40 to 85°C (with no icing or condensation)
Ambient operating humidity
Weight
included. Measurement conditions: Rated voltage operation, Ambient temperature: 23°C
63−64.
2. Performance characteristics are based on a coil temperature of 23°C.
3. The value given for the maximum voltage is for voltages applied Instantaneously to the Relay coil (at an ambient temperature of 23°C)
and not continuously.
24 VDC
http://www.ia.omron.com/
Mechanical
Rated load
Destruction
Malfunction
Mechanical
Electrical
Item
Rated current
4 poles: 15
6 poles: 20.8
(mA)
100 mΩ max.
20 ms max.
10 ms max.
20 ms max.
36,000 operations/h
1,800 operations/h
1,000 MΩ min. (at 500 VDC)
Between coil contacts/different poles: 3,000 VAC, 50/60 Hz for 1 min.
Between poles 1−2, 2−3, and 3−4: 3,000 VAC, 50/60 Hz for 1 min.
Between poles 4−5 and 5−6 (in 6-pole relays): 2,500 VAC, 50/60 Hz for 1 min.
Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min.
10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
1,000 m/s
100 m/s
10,000,000 operations min. (at approx. 36,000 operations/h)
100,000 operations min. (at the rated load and approx. 1,800 operations/h)
5 VDC, 1 mA
5% to 85%
4 poles: Approx. 25 g
6 poles: Approx. 29 g
Load
2
2
Coil resistance
4 poles: 1,600
6 poles: 1,152
6 A at 250 VAC, 6 A at 30 VDC
(Ω)
250 VAC, 125 VDC
Resistive load
6 A
6 A
Must operate
voltage (V)
75% max.
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
Must release
voltage (V)
10% min.
voltage (V)
110%
Max.
Power consumption
4 poles: Approx. 360
6 poles: Approx. 500
(mW)
G7SB
2