r4f2426 Renesas Electronics Corporation., r4f2426 Datasheet - Page 127

no-image

r4f2426

Manufacturer Part Number
r4f2426
Description
16-bit Single-chip Microcomputer H8s Family / H8s/2400 Series
Manufacturer
Renesas Electronics Corporation.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
r4f24268NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24268NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24268NVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24268NVRFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24268NVZFQV
Manufacturer:
REA
Quantity:
150
Part Number:
r4f24268NVZFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
r4f24269NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
r4f24269NVFQV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
4.7
Illegal instruction exception handling starts when the CPU executing an illegal instruction code is
detected. Illegal instruction exception handling can be executed at all times in the program
execution state.
The illegal instruction exception handling is as follows:
1. The values in the PC, CCR, and EXR are saved in the stack.
2. The interrupt mask bit is updated and the T bit is cleared to 0.
3. An exception handling vector table address corresponding to the exception is generated, the
Table 4.5 shows the status of CCR and EXR after execution of illegal instruction exception
handling.
Table 4.5
Legend:
1:
0:
—: Retains value prior to execution
Illegal instruction codes will not be searched for in the fields that do not affect instruction
definitions, such as the EA extension or register fields. Instruction codes for an instruction formed
with several words are detected independently, and combined instruction codes are not detected.
Undefined instruction codes must not be executed. The general register contents after execution of
an undefined instruction code or illegal instruction exception handling cannot be guaranteed. The
stack pointer during illegal instruction exception handling and the PC value that will be saved are
also not guaranteed.
Interrupt Control Mode
0
2
start address of the exception service routine is loaded from the vector table to the PC, and
program execution starts from that address.
Set to 1
Cleared to 0
Illegal Instruction Exception Handling
Status of CCR and EXR after Illegal Instruction Exception Handling
I
1
1
CCR
UI
Rev. 1.00 Sep. 19, 2008 Page 99 of 1270
T
0
Section 4 Exception Handling
EXR
REJ09B0466-0100
I2 to I0

Related parts for r4f2426