14.6.7
Name:
Address:
Access:
• ACKUPD: Acknowledge for Update
0 = Time and calendar registers cannot be updated.
1 = Time and calendar registers can be updated.
• ALARM: Alarm Flag
0 = No alarm matching condition occurred.
1 = An alarm matching condition has occurred.
• SEC: Second Event
0 = No second event has occurred since the last clear.
1 = At least one second event has occurred since the last clear.
• TIMEV: Time Event
0 = No time event has occurred since the last clear.
1 = At least one time event has occurred since the last clear.
The time event is selected in the TIMEVSEL field in RTC_CR (Control Register) and can be any one of the following
events: minute change, hour change, noon, midnight (day change).
• CALEV: Calendar Event
0 = No calendar event has occurred since the last clear.
1 = At least one calendar event has occurred since the last clear.
The calendar event is selected in the CALEVSEL field in RTC_CR and can be any one of the following events: week
change, month change and year change.
240
31
23
15
7
SAM3N
RTC Status Register
30
22
14
RTC_SR
0x400E1478
Read-only
6
29
21
13
5
CALEV
28
20
12
4
TIMEV
27
19
11
3
SEC
26
18
10
2
ALARM
25
17
9
1
11011A–ATARM–04-Oct-10
ACKUPD
24
16
8
0