RCLXT16706FE Intel, RCLXT16706FE Datasheet - Page 267

no-image

RCLXT16706FE

Manufacturer Part Number
RCLXT16706FE
Description
Manufacturer
Intel
Datasheet

Specifications of RCLXT16706FE

Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (min)
2.97V
Operating Supply Voltage (max)
3.63V
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Lead Free Status / Rohs Status
Not Compliant
11.5
11.5.1
Datasheet
15:14
12:11
Bit
Bit
13
10
3
2
1
0
Unused
MstApsFiltCnfg
Unused
MstAisDetCnt
LosSt
LockSt
LofSt
OofSt
Name
SONET/SDH Receive Multiplexer Section Termination
Channel Registers
R_MST_C—Receive MST Configuration ((1cc)90H)
Name
Present status of the internal Loss of Signal (LOS) detect:
'0' = No LOS
'1' = LOS
Present status of the external receive Loss of Clock Synchronization
(RLOCK) input alarm:
'0' = No RLOCK
'1' = RLOCK
Present status of Loss of Frame detect:
'0' = No LOF
'1' = LOF
Present status of Out of Frame detect:
'0' = No OOF
'1' = OOF
51/155/622/2488 Mbit/s SONET/SDH Cell/Packet Interface — Intel IXF6048
Configures the filtering of the receive K1 and K2 APS bytes (either a
single APS channel or two independent channels):
'1' = K1 and K2 APS bytes are filtered and updated together in
register R_K2K1. If K1/K2 value is stable for 3 consecutive frames,
K1 and K2 bits are updated in register R_K2K1.
'0' = K1 and K2 APS bytes are independently filtered and updated in
register R_K2K1. If K1 (resp. K2) value is stable for 3 consecutive
frames, then K1 (resp K2) bits are updated in register R_K2K1.
Configures the number of consecutive received K2 bytes that must
have their RDI bits equal to or different from '111' for the MstAisSt
alarm (register S_MUX bit[0]) to be updated:
'1' = MstAisSt alarm sets when '111' is received in K2-RDI bits for 5
consecutive frames and clears if K2-RDI bits differ from '111' in 5
consecutive frames.
'0' = MstAisSt alarm sets when '111' is received in K2-RDI bits for 3
consecutive frames, and clears if K2-RDI bits differ from '111' in 3
consecutive frames. (SDH)
Description
Description
Type
Type
R/W
R/W
R
R
R
R
Default
Default
'X'
'X'
'X'
'X'
'0'
'1'
267