KIT_TC1797_SK Infineon Technologies, KIT_TC1797_SK Datasheet - Page 53

no-image

KIT_TC1797_SK

Manufacturer Part Number
KIT_TC1797_SK
Description
KIT STARTER AUDO FUTURE TC1797
Manufacturer
Infineon Technologies
Series
Audo Futurer
Type
MCUr

Specifications of KIT_TC1797_SK

Contents
Board, Adapters, Cables, CD, Power Supply
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
TC1797
Other names
KITTC1797SKIN
Errata Sheet
Functional Deviations
Scope:
The erratum is limited to the case of simultaneous generation of internal signals
’integration successful on X’ on one channel and ’integration abort Y’ on the
other channel.
Effects:
In the described cases the E-Ray either is stuck in startup states or extends the
startup by at least two cycles.
Workaround
Use
a
timer
to
measure
how
long
the
E-Ray
stays
in
state
INTEGRATION_COLDSTART_CHECK
or
INTEGRATION_CONSISTENCY_CHECK. If the timeout is reached, re-enter
the startup state by using the CHI commands READY and RUN.
FlexRay_AI.075 Detection of parity errors outside immediate scope
Description:
The protocol engine reads at least the first two words of its Transient Buffer and
one word more than required by the payload count for each transmitted
message, even if no data is needed (null frame or payload count is zero). If a
parity error is detected when the protocol engine reads from the Transient
Buffer, the transmitted message is invalidated by setting its CRC code to zero.
Scope:
The erratum is limited to the case where a parity error occurs in one of the words
in the Transient Buffer that are read but not needed for a particular message.
Effects:
The transmitted message is invalidated.
TC1797, EES-AC, ES-AC, AC
53/101
Rel. 1.3, 18.12.2009