TXC-06312BIOG Transwitch Corporation, TXC-06312BIOG Datasheet - Page 164

no-image

TXC-06312BIOG

Manufacturer Part Number
TXC-06312BIOG
Description
Manufacturer
Transwitch Corporation
Datasheet

Specifications of TXC-06312BIOG

Lead Free Status / Rohs Status
Supplier Unconfirmed
PRELIMINARY TXC-06312B-MB, Ed. 2
June 2005
PHAST-12N Device
DATA SHEET
TXC-06312B
Offset
Offset
0x000A 15 - 0
0x000C 15 - 0
0x000E 15 - 0
0x0000 0
0x0002
0x0014
0x0000 PoissonCommon_Config
0x0002 15 - 0
0x0004 15 - 0
0x0006 15 - 0
0x0008 15 - 0
0x0010 15 - 0
0
1
2
Bits
Bits
Table 26: Section BER Detection Configuration
Table 27: Poisson Distribution BER Detection
PoissonErrorCheck
PoissonDetector_Config
BurstyDetector_Config
DEG_Use125usCounter
EXC_Use125usCounter
BurstProtection
DEG_RecoveryErrorThreshold
DEG_RecoveryWindowSize
EXC_DetectionErrorThreshold
EXC_RecoveryErrorThreshold
EXC_RecoveryWindowSize
DEG_DetectionErrorThreshold
DEG_DetectionWindowSize
EXC_DetectionWindowSize
Name
Name
-
Memory Maps and Bit Descriptions
0xFFFF Range 1 to 65535
0xFFFF Range 1 to 65535
0xFFFF Range 1 to 65535
0xFFFF Range 1 to 65535
0xFFFF Range 1 to 65535
0xFFFF Range 1 to 65535
Init
Init
0x0 Assume Poisson error distribution when 0x1, bursty distribution
0x0 Use 125 us interval length for DEG detection when 0x1, otherwise
0x0 Use 125 us interval length for EXC detection when 0x1, otherwise
0x1 Range 1 to 65535
0x1 Range 1 to 65535
0x0 Enables Burst Protection when 0x1.
when 0x0.
T_BIP_PoissonDetector_Config
Configuration for DEG/EXC detection, assuming Poisson distribu-
tion of errors.
T_Line_BIP_BurstyDetector_Config
Configuration for DEG detection, assuming bursty distribution of
errors.
500 us interval length.
500 us interval length.
Minimum number of bit errors within a window for DEG detection.
Window size for DEG detection in 125/500 us intervals.
Allowed number of bit errors within a window for DEG recovery
(error threshold for which the DEG state will not be exited).
Window size for DEG recovery in 125/500 us intervals.
Minimum number of bit errors within a window for EXC detection.
Window size for EXC detection in 125/500 us intervals.
Maximum allowed number of bit errors within a window for EXC
recovery (error threshold for which the EXC state will not be
exited).
Window size for EXC recovery in 125/500 us intervals.
(T_TOH_MONITOR_BIP_Detector_Config)
(T_BIP_PoissonDetector_Config)
-
Description
Description
(See page
(See page
164)
165)
1 6 4 o f 2 0 2