Your Turn – Testing the Left Wheel
Now, it’s time to run the same test on the left wheel as shown in Figure 3-15. This
involves modifying RightServoTest.bs2 so that the
servo connected to P13 instead of the servo connected to P12.
All you have to do is change the three
instead of
ACTIVITY #3: START/RESET INDICATOR CIRCUIT AND PROGRAM
When the voltage supply drops below the level a device needs to function properly, it’s
called brownout.
processor and program memory chips go dormant until the power supply voltage returns
to normal levels. A drop below 5.2 V at Vin results in a drop below 4.3 V at the BASIC
Stamp’s internal voltage regulator output. A circuit called a brownout detector on the
BASIC Stamp is always on the lookout for this condition. When brownout occurs, the
brownout detector disables the BASIC Stamp’s processor and program memory.
Save RightServoTest.bs2 as LeftServoTest.bs2.
Change the three
PULSOUT 12
Save and then run the program.
Verify that it makes the left servo turn clockwise for 3 seconds, stops for 1
second, then makes the servo turn counterclockwise for 3 seconds.
If the left wheel/servo does not behave as predicted, see the Servo Trouble
Shooting section on page 104.
If the left wheel/servo does behave properly, then your Boe-Bot is functioning
properly, and you are ready to move on to the next activity.
PULSOUT 12
The BASIC Stamp protects itself from brownout by making its
.
.
PULSOUT
Clockwise 3 seconds
Stop 1 second
Counterclockwise 3 seconds
commands so that they read
PULSOUT
commands so that they read
PULSOUT
Figure 3-15
Testing the Left
Wheel
commands are sent to the
PULSOUT 13
PULSOUT 13
instead of