MCHC908MR8CFAE Freescale Semiconductor, MCHC908MR8CFAE Datasheet - Page 180

IC MCU 8K FLASH 8MHZ PWM 32-LQFP

MCHC908MR8CFAE

Manufacturer Part Number
MCHC908MR8CFAE
Description
IC MCU 8K FLASH 8MHZ PWM 32-LQFP
Manufacturer
Freescale Semiconductor
Series
HC08r
Datasheet

Specifications of MCHC908MR8CFAE

Core Processor
HC08
Core Size
8-Bit
Speed
8MHz
Connectivity
SCI
Peripherals
LVD, POR, PWM
Number Of I /o
16
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 7x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
32-LQFP
Controller Family/series
HC08
No. Of I/o's
16
Ram Memory Size
256Byte
Cpu Speed
8MHz
No. Of Timers
2
Rohs Compliant
Yes
Processor Series
HC08MR
Core
HC08
Data Bus Width
8 bit
Data Ram Size
64 B
Interface Type
SCI, SPI
Maximum Clock Frequency
8 MHz
Number Of Programmable I/os
32
Number Of Timers
4
Operating Supply Voltage
0 V to 5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Development Tools By Supplier
FSICEBASE, M68CBL05CE
Minimum Operating Temperature
- 40 C
On-chip Adc
8 bit, 8 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCHC908MR8CFAE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Pulse-Width Modulator for Motor Control
9.12.8 Fault Control Register
Technical Data
180
This register controls the fault protection circuitry.
Reset:
FMODE1 — Fault Mode Selection for Fault Pin 1 Bit (Automatic versus
Manual Mode)
FINT1 — Fault 1 Interrupt Enable Bit
FMODE4 — Fault Mode Selection for Fault Pin 4 Bit (Automatic versus
Manual Mode)
dress:
Read:
Write:
Pulse-Width Modulator for Motor Control (PWMMC)
Ad-
This read/write bit allows the user to select between automatic and
manual mode faults. For further description of each mode, see
9.7 Fault
This read/write bit allows the CPU interrupt caused by faults on fault
pin 1 to be enabled. The fault protection circuitry is independent of this
bit and will always be active. If a fault is detected, the PWM pins will
still be disabled according to the disable mapping register.
This read/write bit allows the user to select between automatic and
manual mode faults. For further description of each mode, see
9.7 Fault
1 = Automatic mode
0 = Manual mode
1 = Fault pin 1 will cause CPU interrupts.
0 = Fault pin 1 will not cause CPU interrupts.
1 = Automatic mode
0 = Manual mode
$0022
FINT4
Bit 7
0
Protection.
Protection.
Figure 9-39. Fault Control Register (FCR)
= Unimplemented
FMODE
6
4
0
5
0
4
0
3
0
MC68HC908MR8 — Rev 4.1
Freescale Semiconductor
2
0
FINT1
1
0
FMODE
Bit 0
1
0

Related parts for MCHC908MR8CFAE