AT91SAM9M10-CU Atmel, AT91SAM9M10-CU Datasheet - Page 837

IC MCU 16/32BIT ARM9 324TFBGA

AT91SAM9M10-CU

Manufacturer Part Number
AT91SAM9M10-CU
Description
IC MCU 16/32BIT ARM9 324TFBGA
Manufacturer
Atmel
Series
AT91SAMr
Datasheets

Specifications of AT91SAM9M10-CU

Core Processor
ARM9
Core Size
16/32-Bit
Speed
400MHz
Connectivity
EBI/EMI, Ethernet, I²C, SPI, SSC, UART/USART, USB
Peripherals
AC'97, DMA, LCD, POR, PWM, WDT
Number Of I /o
160
Program Memory Size
64KB (64K x 8)
Program Memory Type
ROM
Ram Size
128K x 8
Voltage - Supply (vcc/vdd)
0.9 V ~ 1.1 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
324-TFBGA
Processor Series
AT91SAMx
Core
ARM926EJ-S
Data Bus Width
32 bit
Data Ram Size
32 KB
Interface Type
2-Wire, SPI, USART
Maximum Clock Frequency
133 MHz
Number Of Programmable I/os
5
Number Of Timers
2 x 16 bit
Operating Supply Voltage
1.65 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
JTRACE-ARM-2M, MDK-ARM, RL-ARM, ULINK2
Development Tools By Supplier
AT91SAM-ICE, AT91-ISP, AT91SAM9M10-G45-EK
Controller Family/series
AT91
No. Of I/o's
160
Ram Memory Size
64KB
Cpu Speed
400MHz
No. Of Timers
2
Rohs Compliant
Yes
Cpu Family
AT91
Device Core
ARM926EJ-S
Device Core Size
32b
Frequency (max)
400MHz
Total Internal Ram Size
64KB
# I/os (max)
160
Number Of Timers - General Purpose
7
Operating Supply Voltage (typ)
1.8/2.5/3.3V
Operating Supply Voltage (max)
1.1/1.95/3.6V
Operating Supply Voltage (min)
0.9/1.65/1.8/3V
On-chip Adc
8-chx10-bit
Instruction Set Architecture
RISC
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
324
Package Type
TFBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM9M10-CU
Manufacturer:
Atmel
Quantity:
996
Part Number:
AT91SAM9M10-CU
Manufacturer:
Atmel
Quantity:
10 000
837
AT91SAM9M10
the required number of packets per microframe, otherwise, the host will notice a sequencing
problem.
A response should be made to the first token IN recognized inside a microframe under the fol-
lowing conditions:
At the end of a microframe in which at least one data bank has been transmitted, if less than
NB_TRANS banks have been validated for that microframe, an error condition is flagged
(ERR_TRANS is set in UDPHS_EPTSTAx).
Cases of Error (in UDPHS_EPTSTAx)
• If at least one bank has been validated, the correct DATAx corresponding to the programmed
• If no bank is validated yet, the default DATA0 ZLP is answered and underflow is flagged
• If no data bank has been validated at the time when a response should be made for the
• If no data bank has been validated at the time when a response should be made for the last
• If at the end of a microframe no valid token IN has been recognized, no data bank is flushed
• ERR_FL_ISO: There was no data to transmit inside a microframe, so a ZLP is answered by
• ERR_FLUSH: At least one packet has been sent inside the microframe, but the number of
• ERR_TRANS: At least one packet has been sent inside the microframe, but the number of
• ERR_FL_ISO + ERR_FLUSH: At least one packet has been sent inside the microframe, but
• ERR_FL_ISO + ERR_TRANS: At least one packet has been sent inside the microframe, but
• ERR_FLUSH + ERR_TRANS: The first token IN has been answered and it was the only one
Number Of Transactions per Microframe (NB_TRANS) should be answered. In case of a
subsequent missed or corrupted token IN inside the microframe, the USB 2.0 Core available
data bank(s) that should normally have been transmitted during that microframe shall be
flushed at its end. If this flush occurs, an error condition is flagged (ERR_FLUSH is set in
UDPHS_EPTSTAx).
(ERR_FL_ISO is set in UDPHS_EPTSTAx). Then, no data bank is flushed at microframe
end.
second transaction of NB_TRANS = 3 transactions microframe, a DATA1 ZLP is answered
and underflow is flagged (ERR_FL_ISO is set in UDPHS_EPTSTAx). If and only if remaining
untransmitted banks for that microframe are available at its end, they are flushed and an error
condition is flagged (ERR_FLUSH is set in UDPHS_EPTSTAx).
programmed transaction of a microframe, a DATA0 ZLP is answered and underflow is flagged
(ERR_FL_ISO is set in UDPHS_EPTSTAx). If and only if the remaining untransmitted data
bank for that microframe is available at its end, it is flushed and an error condition is flagged
(ERR_FLUSH is set in UDPHS_EPTSTAx).
and no error condition is reported.
default.
token IN received is lesser than the number of transactions actually validated (TX_BK_RDY)
and likewise with the NB_TRANS programmed.
token IN received is lesser than the number of programmed NB_TRANS transactions and the
packets not requested were not validated.
the data has not been validated in time to answer one of the following token IN.
the data has not been validated in time to answer one of the following token IN and the data
can be discarded at the microframe end.
received, a second bank has been validated but not the third, whereas NB_TRANS was
waiting for three transactions.
6355B–ATARM–21-Jun-10

Related parts for AT91SAM9M10-CU