TMP86xy49UG/F/NG Toshiba, TMP86xy49UG/F/NG Datasheet - Page 189

no-image

TMP86xy49UG/F/NG

Manufacturer Part Number
TMP86xy49UG/F/NG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMP86xy49UG/F/NG

Package
LQFP64/QFP64/SDIP64
Rom Types (m=mask,p=otp,f=flash)
M/P/F
Rom Size
16/32/60
Ram Size
512/1K/2K
Driver Led
13
Driver Lcd
-
Spi/sio Channels
2
Uart/sio Channels
2
I2c/sio Channels
1
High-speed Serial Output
-
Adc 8-bit Channels
-
Adc 10-bit Channels
16
Da Converter Channels
-
Timer Counter 18-bit Channel
-
Timer Counter 16-bit Channel
2
Timer Counter 8-bit Channel
4
Motor Channels
-
Watchdog Timer
Y
Dual Clock
Y
Clock Gear
-
Number Of I/o Ports
56
Power Supply (v)
4.5 to 5.5
14.3 Function
(2)
(3)
SIO1RDB, SIO1SR<RXF> is cleared to “0”.
level by an automatic-wait function when all of the bit set in the data has been transmitted.
the received data from SIO1RDB, or reading the received data from SIO1RDB after writing the next
data to SIO1TDB.
Then, transmit/receive operation is restarted after maximum 1 cycle of serial clock.
In external clock operation, reading the received data from SIO1RDB and writing the next data to
SIO1TDB must be finished before the shift operation of the next data begins.
If the transmit data is not written to SIO1TDB after SIO1SR<TXF> is set to “1”, transmit error
occurs immediately after shift operation is started. When the transmit error occurred,
SIO1SR<TXERR> is set to “1”.
If received data is not read out from SIO1RDB before next shift operation starts after setting
SIO1SR<RXF> to “1”, receive error occurs immediately after shift operation is finished. When the
receive error has occurred, SIO1SR<RXERR> is set to “1”.
During the transmit/receive operation
When data is written to SIO1TDB, SIO1SR<TXF> is cleared to “0” and when a data is read from
In internal clock operation, in case of the condition described below, the serial clock stops to “H”
The automatic wait function is released by writing the next transmit data to SIO1TDB after reading
Stopping the transmit/receive operation
There are two ways for stopping the transmit/receive operation.
• Next transmit data is not written to SIO1TDB after reading a received data from SIO1RDB.
• Received data is not read from SIO1RDB after writing a next transmit data to SIO1TDB.
• Neither SIO1TDB nor SIO1RDB is accessed after transmission.
• The way of clearing SIO1CR<SIOS>.
• The way of setting SIO1CR<SIOINH>.
When SIO1CR<SIOS> is cleared to “0”, transmit/receive operation is stopped after all trans-
fer of the data is finished. When transmit/receive operation is finished, SIO1SR<SIOF> is
cleared to “0” and SO1 pin is kept in high level.
In external clock operation, SIO1CR<SIOS> must be cleared to “0” before SIO1SR<SEF> is
set to “1” by beginning next transfer.
Transmit/receive operation is stopped immediately after SIO1CR<SIOINH> is set to “1”. In
this case, SIO1CR<SIOS>, SIO1SR register, SIO1RDB register and SIO1TDB register are
initialized.