PS024611-0408
ADC Clock
BUSY
ADC Interrupt
ADC Timer 0 Capture
Reference Buffer
Internal Voltage Reference Generator
Figure 38
The ADC can generate an interrupt request when a conversion is completed. An interrupt
request that is pending when the ADC is disabled is not automatically cleared.
The Timer 0 count is captured for every ADC conversion. The capture of the Timer 0 count
occurs after the programmed sample time is complete for every conversion and stored in
the ADC Timer Capture register (ADCTCAP).
The reference buffer (RBUF) supplies the reference voltage for the ADC. When enabled,
the internal voltage reference generator supplies the ADC and the voltage is available on
the V
externally through the V
register.
The Internal Voltage Reference Generator provides the voltage (VR2) for the RBUF.
VR2 is 2 V.
1
REF
2
pin. When RBUF is disabled, the ADC must have the reference voltage supplied
displays the timing of an ADC convert period.
3
4
Figure 38. ADC Convert Timing
5
REF
Convert Period
6
13-Clock
pin. RBUF is controlled by the REFEN bit in the ADC Control
7
8
9
10
11
Z8FMC16100 Series Flash MCU
12
13
Product Specification
14
15
16
ADC Interrupt
17
200